5. Remove gear motor:
§ Remove gear motor insulation (Fig. 15.1).
§ Remove 1/4-20 screw, retainer, and spacer (Fig. 15.2).
§ Remove two 1/2" bolts (Fig. 15.3).
§ Pull gear motor from auger (Fig. 15.4).
§ Remove main housing insulation (Fig. 15.5).
6. Remove all traces of petro-gel from auger shaft.
7.
Remove main housing:
§ Use an allen wrench to remove 3/16" allen screws (3)
(Fig. 16.1).
§ Remove shaft insulation (Fig. 16.2).
§ Remove main housing (Fig. 16.3).
8. Remove and discard mating ring and seal
(Fig. 17.1).
9. Carefully remove auger (Fig. 17.2).
WARNING!
Use caution when removing auger. The auger is
very sharp - handle with care to avoid personal
injury.
Fig. 15
3
1
Fig. 16
1
1
1
Fig. 17
1
19
4
2
3
3
2
1
2
5