12

Startup, Operation and Maintenance

12.1

Commissioning

CAUTION
Preparation
Execution
12.2

Operation

12.3

Deactivation

Material damage due to errors in the controls of motors and moving el‐
ements! Unclear operating states and product data!
⇒ Do not carry out commissioning if connections, operating states or product
data are unclear or faulty!
⇒ Do not carry out commissioning if the safety and monitoring equipment of the
system is damaged or not in operation.
⇒ Damaged products must not be operated!
⇒ Contact Rexroth for missing information or support during commissioning!
The following commission notes refer to the MKE motors as part of a drive-
system with drive and control unit.
1.
Keep the documentation of all applied products ready.
2.
Check the products for damage.
3.
Check all mechanical and electrical connections.
4.
Activate the safety and monitoring equipment of the system.
When all requirements are met, proceed as follows:
1.
Activate the optional blower.
2.
Carry out the commission of the drive system according to the instructions
provided in the respective documentation. You can find the respective in‐
formation in the functional description of the drive controllers.
Commissioning of drive controllers and the control unit may require addi‐
tional steps. The inspection of the functioning and performance of the systems
is not part of the commissioning of the motor; instead, it is carried out within the
framework of the commissioning of the machine as a whole. Observe the in‐
structions and regulations given by the machine manufacturer.
Make sure that the ambient conditions described in Chapter
Height and Ambient Temperature" on page 81
In the case of malfunctions or maintenance, or to deactivate the motors, pro‐
ceed as follows:
1. Observe the instructions of the machine documentation.
2. Use the control commands to bring the drive to a controlled standstill.
3. Switch off the power and control voltage of the drive controller.
4. Switch off the main switch of the machine.
5. Secure the machine against accidental movements and against unau‐
thorized operation.
6. Wait for the discharge time of the electrical systems to expire and then
disconnect all electrical connections.
7. Before dismantling, secure the motor against falling or movements before
disconnecting the mechanical connections.
Electric Drives
| Bosch Rexroth AG
and Controls
Startup, Operation and Maintenance
are kept during operation.
111/131