68/131
Bosch Rexroth AG | Electric Drives
Connection Technique
8.3
Connection according to American Standard (UL)
Power and encoder connection
Rexroth MKE Synchronous Motors | Project Planning Manual
and Controls
on the motor flange). Protective conductor cross-section see
protective conductor" on page
Fig.8-5:
Connection overview according to American standard
The connection of the MKE motors, according to American standard, consists
of the following components:
●
a power connector, incl. connection for temperature sensor and holding
brake, single-wire construction
●
encoder connection, standard-cable construction
●
additional outside connection for an equipotential bonding conductor (ac‐
cording to EN 50014: 1992)
The connection cable of the MKE motors are to be realised through a special
cable duct into the motor. The ca. 1.5 m long connection cables have to be led
through a ¾ inch metal pipe into an approved Ex terminal box (see
Connection variants MKE motors" on page
lead from an Ex terminal box to a drive control device.
66.
65). Standard connection cables
fig. 8-2 " Additional
fig. 8-1 "