3. Use the light and mirror to examine the interior of the combustion chamber for
cracks or separations. Also, inspect the burner mounting flange (m) for damage.
4. Have an assistant shine the light (q) over the exterior shell of the combustion
chamber while you peer through the hole in the mounting flange. Look for signs
of light inside the combustion chamber.
Outcome
Do not use the machine if any of the following conditions exist. Contact Wacker
Neuson Product Support for assistance.
■ Cracks or separations are discovered in the heat exchanger
■ Soot is visible on the exterior (air side) of the heat exchanger
■ There are cracks or damage to the burner mounting flange
Note: Light surface rust is normal.
Reassembly
Perform the procedure below to reassemble the machine after inspecting the heat
exchanger.
1. Re-install the burner.
2. Re-install the heat shields.
3. Reattach the side panels.
Result
The heat exchanger has now been inspected.