STEP 1: Remove detergent suc-
tion tube from container and insert
into one gallon of fresh water. Slide
nozzle forward for low pressure or
to connect black detergent nozzle.
Pull trigger on spray gun and siphon
water for one minute.
STEP 4: Press
STEP 5: Disconnect the garden
trigger to release
hose from the water inlet on the
water pressure.
machine.
Pump Storage
CAUTION: Always store your pres-
sure washer in a location where the
temperature will not fall below 32° F
(0° C). The pump in this machine is
susceptible to permanent damage if
CAUTION
frozen.
FREEZE DAMAGE IS NOT COVERED BY WAR-
RANTY.
If you must store your pressure washer in a location
where the temperature is below 32° F, you can minimize
the chance of damage to your machine by draining your
machine as follows:
1. Stop the pressure washer and detach supply hose
and high pressure hose. Squeeze the trigger of the
spray gun to drain all water from the wand and
hose.
2. Restart pressure washer and let it run briefly (about
5 seconds) until water no longer discharges from
the high pressure outlet.
SHUTTING DOWN AND CLEAN-UP
STEP 2: Turn off machine.
Pump
Water
Inlet

STORAGE

LANDA PE 8.913-998.0
STEP 3: Turn off water
supply.
High Pressure
Outlet
STEP 6: Disconnect the high
pressure hose from high pres-
sure outlet.
Safety
Latch
STEP 7: Engage
t h e s p ray g u n
safety lock.
9