4.4

Max. dimensions

The maximum dimensions of the burner and flange are shown in Fig. 1.
D
F
D9675
G
Model
A
B
BG6.1D
300
345
BG6.1D TL
300
345
BG7.1D
300
345
4.5

Firing rate

The burner output is chosen from within the diagram area (Fig. 2).
This area is known as the "firing rate" and provides the burner
output according to the pressure in the combustion chamber.
The work point may be found by plotting a vertical line from the
desired delivery and a horizontal line from the pressure in the
combustion chamber. The intersection of these two lines is the
work point which must lie within the firing rate.
2,6
2,4
2,2
2,0
1,8
1,6
1,4
1,2
1,0
0,8
0,6
0,4
0,2
0
0,2
0,3
4
5
50
60
D9674
20015403
Technical description of the burner
E
Ø H
Ø I
C
D
E
285
228
284
285
228
363
285
247
394
985T
6
7
8
70
80
90
A
F
G
Ø H
12
36
97
12
36
97
12
36
116
The firing rate was obtained considering an ambi-
ent temperature of 20 °C and an atmospheric
pressure of 1013 mbar (approx. 100 m above sea
level), with the combustion head adjusted as
WARNING
shown in Tab. A.
986T
9
10
11
100
110
120
130
8
GB
Ø I
L
M
N
131
189
106
83
131
189
106
83
165
213
127
99
EN 303-2
12
13
Light oil output – kg/h
140
150
Thermal power – kW
L
M
O
P
Fig. 1
O
P
140
170
140
170
160
190
Fig. 2