Condition
Display Text (Screen1)
Humiditrol and Dew
point disable and Out-
door sensor reads out
of range (installer set-
ting OUTDOOR SEN-
SOR is set to YES)
Hum sensor error
(With Humidifier or
Dehumidifier): condi-
tions are
0%:
Stat will detect
error
0−10%:Stat may de-
tect error
10−90%:
Normal
operation
90−93%:
Stat
may detect error
93%: Stat will detect
error
Hum sensor error
(Without Humidifier or
Dehumidifier): sensor
reads out of range 0%
to 100%
L input detection
HVAC ERROR DETECTED
Media Filter
UV Lamp
Humidity Pad
Routine sys check up
ROUTINE SYS CHECK−UP
PureAir
mainte-
REPLACE METAL INSERT
nance
506230−01 05/09
Display Text
(Screen2)
NO OUTDOOR SENSOR
REMIND CLEAR SER-
VICE
HUM SENSOR ERROR
REMIND
SERVICE
REMIND/SERVICE
HUM SENSOR ERROR
REMIND
SERVICE
REMIND/SERVICE
REMIND
SERVICE
REMIND/SERVICE
REPLACE MEDIA FILTER
See REMIND/RESET
REMIND
RESET
REPLACE UV LAMP
See REMIND/RESET
REMIND
RESET
REPLACE HUM PAD
See REMIND/RESET
REMIND
RESET
See REMIND/RESET
REMIND
RESET
See REMIND/RESET
REMIND
RESET
System Action
See
The display of Outdoor sensor
REMIND/CLEAR/
from HOME will be turned
SERVICE notes
OFF. If user turns on the dis-
play from USER SETTINGS,
this error is displayed again.
NOTE: This error would not
occur if the system is in Arm-
chair programming.
See
All the humidity operation will
stop and the reading for hu-
notes
midity will not be valid. This
message indicates something
seriously wrong with the ther-
mostat.
The display of Indoor Humidity
from HOME will be turned
OFF. If user turns it on again,
the error is displayed.
See
The reading for humidity will
not be valid. This message in-
notes
dicates something seriously
wrong with the thermostat.
The display of Indoor Humidity
from HOME will be turned
OFF. If user turns it on again,
the error is displayed.
See
Message is displayed in the in-
formation display area. Out-
notes
side unit may stop working.
Displayed on both lines on
notes
HOME.
Displayed on both lines on
notes
HOME.
Displayed on both lines on
notes
HOME.
Displayed on both lines on
notes
HOME.
Displayed on both lines on
notes
HOME.
Page 26
Action to Clear /
Recovery Condition
If the outdoor sensor reads a
value within its normal range.
(User can call the dealer to re-
place outdoor sensor). User
can also use CLEAR to erase
the error.
Replace Thermostat
Replace Thermostat
If the L signal is removed, the
message is cleared. OR User
can call the dealer.
User either push RESET or
REMINDER button
User either push RESET or
REMINDER button
User either push RESET or
REMINDER button
User either push RESET or RE-
MINDER button
User either push RESET or RE-
MINDER button
table continued on next page