Fujitsu ARYG12LHTBP Design & Technical Manual page 131

Hide thumbs Also See for ARYG12LHTBP:
Table of Contents

Advertisement

¢ Compressor status output
Signal on compressor operation status is generated when the compressor is running.
 Circuit diagram example
Outdoor unit
control PCB
Connector
+
1
2
Compressor
status
Output signal
 Optional part
Part name
External connect kit
12-2. External output
Connected unit
Vcc
Vcc
Power
supply
+
Load
-
10 m*
Signal
Locally purchased
Operation
Stop
On
Off
Model name
UTY-XWZXZ3
• 1: Power supply
Voltage (Vcc): DC 24 V or less
• 2: Load
DC 500 mA or less
• *: Make the distance from the PCB to the
connected unit within 10 m.
- 125 -
12. External input and output (AOYG45LBTA and AOYG54LBTA)
Exterior
External output wire

Advertisement

Table of Contents
loading

Table of Contents