Split type air conditioner duct type (50hz) (28 pages)
Summary of Contents for Fujitsu ARYG45LHTA
Page 1
SPLIT TYPE AIR CONDITIONER DUCT TYPE (50Hz) Indoor unit Outdoor unit ARYG45LHTA AOYG45LETL ARYG54LHTA AOYG54LETL C ONT E NTS SPECIFICATIONS ....DIMENSIONS..... .
SP E C IFICA TI ONS ELECTRICAL DATA NOISE LEVEL High TYPE Cooling & Heating 47 dB INDOOR UNIT ARYG45LHTA ARYG54LHTA Medium 43 dB INDOOR UNIT OUTDOOR UNIT AOYG45LETL AOYG54LETL 40 dB COOLING CAPACITY 12.5 kW 13.4 kW Cooling 55 dB...
RE FR IG E RAN T SYS T E M D IA GR AM OUTDOOR UNIT INDOOR UNIT Refrigerant Pipe Pressure 15.88mm (5/8") Check Valve 3-way Valve Muffler Pressure Sensor 4-way Valve Heat Heat Check Exchanger Valve Exchanger High Pressure Accumulator Switch Muffler...
CI RCUI T DIAG RAM OUTDOOR UNIT INDICATOR PCB INDOOR UNIT HIGH PRESSURE SWITCH CN101 WHITE BLACK WHITE THERMISTOR CN61 WHITE BLACK ( OUTDOOR TEMP. ) WHITE TRANSFORMER BLACK WHITE THERMISTOR ( PIPE TEMP. ) BLACK WHITE WHITE CN63 MAIN PCB BLACK CN401 CN40...
ER R OR D ETEC TION WIRED REMOTE CONTROL This is possible only on a wired remote control. If an error occurs, the following display will be shown. (“Er” will appear in the set room temperature display.) Error code Unit number of indoor unit EX.
OUTDOOR UNIT Indicator PCB LEDs Buttons ERROR DETECTION Display when an error occurs. PUMP PEAK POWER ERROR DOWN NOISE MODE (L1) (L2) (L3) (L4) (L5) (L6) Blink (Hi speed) Check that the “ERROR” LED blinks, then press the [Enter] button once. For details, refer to the following table.
Page 15
OUTDOOR UNIT TEST RUN Before the test run, refer to he figure and check the following items. Setting method Is the outdoor unit securely installed? Turn on the power of the outdoor unit and enter standby mode. Have you performed gas leakage inspection? PUMP PEAK (Connection joints of various pipes (flang connection, brazing))
Page 16
OUTDOOR UNIT PUMP DOWN Procedure WARNING (1) Check the 3-way valves (both the liquid side and gas side) are opened. Never touch electrical components such as the terminal blocks except the button on (2) Turn the power on. the display board. It may cause a serious accident such as electric shock. PUMP PEAK During the pump-down operation, make sure that the compressor is turned off before...
Page 17
PART S INDOOR UNIT Ref. Description Parts number Plate Top Sub Assy 9372576014 Kit (Panel Front Sub Assy) 9372637029 Panel Fan Assy 9372035009 Motor, Induct 9602802012 Casing A 9372057018 Casing B 9372058015 Sirocco Fan 9372059029 (Connector : black) (Connector : white) Kit (Panel Rear Sub Assy) 9372636022 Room Thermistor...
Page 18
INDOOR UNIT Ref. Description Parts number Power Supply PCB 9705668119 Main PCB (45) 9705246287 Main PCB (54) 9705246294 Transformer (Power) 9704129017 Terminal 3P 9703345012 Terminal 3P 9306489045 Relay 9900294014 Capacitor, Plastic 9900269111 Remote Control 9318593013 2012.04.12...
Page 19
PARTS OUTDOOR UNIT Ref. Description Parts number Ref. Description Parts number Top Panel Sub Assy 9374417056 Motor DC Brushless 9602843039 Front Panel Sub Assy 9374414109 Propeller Fan Assy 9366378020 Sevice Panel Sub Assy 9374415090 Condenser A Sub Assy 9374420261 Emblem Rear 9351355005 Condenser B Sub Assy 9374422081...
OUTDOOR UNIT Control box Ref. Description Parts number Main PCB (AOYG45LETL) 9708690148 Main PCB (AOYG54LETL) 9708690155 Indicator PCB 9708678016 Terminal 9900203023 Filter PCB 9708688015 Thermistor 9704265012 Capacitor PCB 9707257083 Choke Coil 9900624019 ACTPM 9707592016 Transistor PCB 9708647043 Heat Sink 9380358008 Outdoor Thermistor 9900210069 Thermistor Assy (CN63)
Page 21
OUTDOOR UNIT Ref. Description Parts number Ref. Description Parts number 3-way Valve Assy 9379079006 4-way Valve Assy 9374425235 3-way Valve Assy 9379077002 Discharge Pipe Assy 9371581248 Compressor 9810153005 Pressure Switch 9900186012 Accumulator 9379014021 Check Joint Assy 9372802038 Expansion Valve Coil 9970096044 Union joint Assy 9379068000...
Page 22
A C C ESS OR IE S INDOOR UNIT Name and Shape Q'ty Application Part number Special nut A 313005446653 (large flange) For suspending the indoor unit from ceiling Special nut B 313005446759 (small flange) Coupler heat insulation (large) For indoor side pipe joint 9378173569 (large pipe) Coupler heat...
OPTIONAL PARTS Parts name Model name Application Simple remote control UTY-RSN*M For air conditioner operation Wired remote control UTY-RNN*M For air conditioner operation High functional wired remote control UTY-RVN*M Remote sensor unit UTY-XSZX Room temperature sensor External connect kit UTD-ECS5A For control input/output port Long life filter UTD-LF60KA...