is available for that device. Both indoor and outdoor units must have
energy tracking capability for this feature to function fully.
This menu item allows the installer to view the energy usage of each
piece of equipment connected to the system. To return to the previous
screen, touch BACK. To exit the Service menus, touch DONE.
A14231
6.6. Refrigerant Charging: Greenspeed®
Intelligence, 18VS™, 19VS™ Systems
For variable capacity and multi-stage heat pumps and AC units, a
refrigerant charging menu is available to aid in the proper charging of the
system. Enter the menu from the service screens by touching
REFRIGERANT CHARGING.
The option for HTG CHECK CHARGE is only available for heat pump
units, and not available in AC units.
NOTE: See the outdoor equipment Installation Instructions for
information on what conditions CHARGING COOLING and HTG
CHECK CHARGE are available.
6.6.1. Charging
Within the CHARGING COOLING or HTG CHECK screens, the
installer will have the ability to enter the LINESET length and the
VAPOR LINE diameter. After the selections are made, touch NEXT.
69