• Route wires through large hole in mounting plastic. The hole may be
enlarged, if required, to accommodate existing installations; avoid
opening the wire hole more than necessary. Level backplate against
wall (for aesthetic value only; the Evolution Connex Control need not
be level to operate properly) and mark wall through two mounting
holes.
• Drill two 3/16-in (4.8 mm) mounting holes in wall where marked.
• Secure mounting plastic to wall using two screws and anchors
provided.
• Adjust length and routing of each wire to reach each wire entry on the
connector backplate. Strip 1/4-in (6.4 mm) of insulation from each
wire.
• Match and connect thermostat wires to proper terminals on control
backplate. See wiring diagrams in the Wiring Diagrams Section.
• Push any excess wire into the wall. Seal hole in wall to prevent any air
leaks. Air leaking from behind the wall can affect measured
temperature and humidity, and can affect operation.
• Attach Evolution Connex Control to the mounting plastic by lining up
the plastic guides on the back of the control with the opening on the
mounting plastic and push on.
• Perform installation of all other system equipment (i.e. dampers,
humidifier, ventilator, UV lights, etc.). See the equipment and device
installation instructions for details.
• Turn on power to equipment.

4.6. Humidifier Connections

A 24VAC bypass or fan powered humidifier may be installed.
NOTE: Do NOT use a traditional humidistat to control humidifier
operation. If a humidifier is installed, let the Evolution Connex Control
operate humidifier.