Actuator Mounting - Emerson Fisher V150E Instruction Manual

Expanded outlet vee-ball control valve
Table of Contents

Advertisement

Instruction Manual
D103435X012
15. When the above conditions are met, tack weld the taper key (key 4) to the ball ear on the head end of the key (see
figures 8 and 10). Use a:
D 1/8 inch diameter weld on NPS 3x4, 4x6, 6x8 valves,
D 3/16 inch diameter weld on NPS 8x10 and 10x12 valves
16. Use the pry to move the ball tightly against the bearing on the actuator side of the valve to help ensure correct
side-to-side centering of the ball (key 2) on the seal (key 11). See figure 4.
17. Be sure that the HD seal is fully installed in the valve. Carefully rotate the ball to engage the HD seal while applying
force across the middle of the seal to compress the wave spring until the ball is fully engaged. Be cautious during
this process, knowing that excessive force may damage the ball. Keep the ball in the engaged position going
forward.
18. Continue to check the ball's position and re-center if necessary during actuator mounting and packing
adjustments.
For all constructions: Refer to Packing Maintenance, and other procedures as necessary to complete the assembly of
the valve.

Actuator Mounting

Use the appropriate actuator instruction manual, this section of this manual, and figure 9 of this manual when
mounting the actuator or changing actuator styles and positions.
1. To help ensure correct centering of the Vee‐Ball (key 2) on the seal (key 11), be sure the ball is closed when
mounting the actuator (for applications other than Spring Return Fail‐Open).
2. Clean the valve shaft and actuator lever splines to be sure the actuator lever will slide on easily. Only drive the lever
in if absolutely necessary.
3. Carefully wedge the ball solidly against the actuator‐side bearing, using a screwdriver or similar tool inserted
between the lower ear of the ball and the valve body. This will center the ball. See figure 4.
Figure 8. Taper Key Installation
MINIMUM ENGAGEMENT OF TAPER KEY
31B0727‐E
A6035‐1
Table 4. Taper Key Minimum Depth
Valve Size, NPS
3x4, 4x6, 6x8
8x10, 10x12
Table 5. Taper Key Maximum Depth
Valve Size, NPS
3x4, 4x6
6x8
8x10, 10x12
BALL
(KEY 2)
TACK WELD
TAPER KEY
(KEY 4)
MAXIMUM ENGAGEMENT OF TAPER KEY
Minimum Depth To Drive Taper Key After Initial Solid Contact, mm (Inches)
Maximum Depth To Drive Taper Key After Initial Solid Contact, mm (Inches)
DRIVE SHAFT
(KEY 6)
TACK WELD
TAPER KEY
(KEY 4)
4.8 (0.188)
5.6 (0.219)
7.1 (0.281)
7.9 (0.312)
9.5 (0.375)
V150E Valve
July 2017