6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
No.
1
Fan Motor (for indoor)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Louver motor
6-2. Outdoor Unit
No.
1
Compressor
2
Fan Motor
3
Pulse Modulating Valve (PMV) coil
4
4-Way valve coil
5
Reactor
6
Suction temp. sensor
7
Discharge temp. sensor
8
Outside air temp. sensor
9
Heat Exchanger temp. sensor
10
Terminal block
Parts name
Parts name
RAS-25
RAS-35
(TS sensor)
(TD sensor)
(TO sensor)
(TE sensor)
(6 poles)
Type name
ICF-340-30-6
(-)
(-)
24BYJ48-ST
Type name
DX136A1T-40N
DX151A1T-30N
WDF-340-A43-1
CAM-MD12TCTH-5
STF-H01AJ1872A1
CH-69-Z-T
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
JX0-6B
- 19 -
Specifications
DC340V, 42W
10kΩ at 25°C
10kΩ at 25°C
Output (Rated) 4 phase, DC12V
Specifications
3-Phases (4-Poles) ; 1100W
3-Phases (4-Poles) ; 1100W
DC 140-340V ; 43W
DC 12V
AC 220-240V
L = 19mH, 10A
10kΩ at 25°C
62kΩ at 20°C
10kΩ at 25°C
10kΩ at 25°C
AC 250V, 30A