PROBLEM
FQ4000 displays
RECOVERY FAULT
and alarm sounds.
FQ4000 display is
in wrong
temperature scale
(Fahrenheit or
Celsius).
FQ4000 displays
HELP HI-2 or HIGH
LIMIT FAILURE
DISCONNECT
POWER.
FQ4000 displays
TEMPERATURE
PROBE FAILURE.
FQ4000 displays
SERVICE REQUIRED
followed by an error
message.
FQ4000 displays
NO MENU GROUP
AVAILABLE FOR
SELECTION
5.3
Troubleshooting Filtration
PROBLEM
FQ4000 displays
CHANGE FILTER
PAPER?
SAFE MODE – E81
SAFE MODE FAILURE
TECHNICAL
SUPPORT REQUIRED
1-800-421-4101
ENTER PASSCODE
Drain or return
stays open.
PROBABLE CAUSES
Recovery time exceeded maximum
time limit.
Incorrect display option programmed.
Failed high limit
Problem with the temperature
measuring circuitry including the
probe or damaged controller wiring
harness or connector.
An error has occurred which requires
a service technician.
All menu groups have been deleted.
NOTE: ALL RECIPES is not a group that
can be used to cook recipes.
PROBABLE CAUSES
Filter error has occurred, filter paper
clogged, 25-hour filter paper change
prompt has occurred or change
filter paper was ignored on a prior
prompt.
The oil level is low in the vat.
A. Valve Interface Board has failed.
B. Actuator has failed.
CORRECTIVE ACTION
Clear error and silence the alarm by
pressing the check √ button.
Maximum recovery time for gas is
3:15. If the error continues call your
FAS for assistance.
Toggle between F° to C° by
entering Manager settings,
temperature and toggling the
temperature scale. Turn the
controller on to check
temperature. If the desired scale is
not displayed, repeat.
Shut the fryer down immediately
and call your FAS for assistance.
Shut the fryer down and call your
FAS for assistance.
Press X to continue cooking and call
your FAS for assistance. In some
cases, cooking may not be allowed.
Create a new MENU group. Once a
new menu is created, add recipes
to the group (see section 1.10 in
the FQ4000 controller manual).
CORRECTIVE ACTION
Change the filter paper and ensure
the filter pan has been removed
from the fryer for a minimum of 30
seconds. Do NOT ignore CHANGE
FILTER PAPER prompts.
Check the filter pan to ensure all the
oil returned to the vat. Ensure the oil
level is at the top oil level line or
between the two lines. Call 1-800-
421-4101 for the passcode.
Call your FAS for assistance.
5-3