Verathon GlideScope Core Operation & Maintenance Manual

Verathon GlideScope Core Operation & Maintenance Manual

Hide thumbs Also See for GlideScope Core:

Advertisement

Operations & Maintenance Manual

Advertisement

Table of Contents
loading

Summary of Contents for Verathon GlideScope Core

  • Page 1 Operations & Maintenance Manual...
  • Page 2 0900‑5017‑ETEE REV‑05...
  • Page 3 GLIDESCOPE CORE Operations & Maintenance Manual Effective: April 12, 2021 Caution: Federal (United States) law restricts this device to sale by or on the order of a physician.
  • Page 4 International: +61 2 9431 2000 Tel / +61 2 9475 1201 Fax Copyright © 2021 by Verathon Inc. All rights reserved. No part of this manual may be copied or transmitted by any method without the express written consent of Verathon Inc.
  • Page 5: Table Of Contents

    Retsepti teatis ..............................1 HIPAA Privacy ..............................1 Notice to All Users ..............................2 Hoiatused ja ettevaatusabinõud ..........................2 INTRODUCTION ..............................6 GlideScope Core ..............................6 System Parts & Accessories ..........................7 Buttons, Icons, & Connections ..........................8 SYSTEM FEATURES .............................. 14 Home Screen ..............................14 Gallery ................................15 SETTING UP .................................16...
  • Page 6 Procedure 5. Record Video or Take a Snapshot ..................37 Procedure 6. Use the Gallery ........................38 REPROCESSING ..............................43 HOOLDUS JA OHUTUS ............................44 Korralised ülevaatused ............................44 GlideScope Core’i aku ............................44 Süsteemi tarkvara .............................44 Seadme parandamine ............................45 Seadme kõrvaldamine ............................45 LIMITED WARRANTY ............................46 PRODUCT SPECIFICATIONS ..........................48...
  • Page 7: Important Information

    (Core 10) or Dual View (Core 15) options. PRODUCT DESCRIPTION GlideScope Core is an all‑in‑one system offering immediate access to the tools you need to visualize the airway. Designed around a 10” or 15” high‑definition, touchscreen monitor and comprehensive workstation, GlideScope Core delivers elevated visibility and improved workflow.
  • Page 8: Notice To All Users

    NOTICE TO ALL USERS Verathon recommends that all users read this manual before using the system. Failure to do so may result in injury to the patient, may compromise the performance of the system, and may void the system warranty.
  • Page 9 (USA) OSHA standardile 29 CFR 1910.1030 „Bloodborne Pathogens“ või samaväärsele standardile. HOIATUS Seda toodet võib puhastada ainult GlideScope’i toodete töötlemisjuhendis (tootenumber 0900‑5032) esitatud heakskiidetud menetlustega. Verathon soovitab loetletud puhastusmeetodeid tõhususe või komponentide materjalidega sobivuse alusel. HOIATUSED: TOOTEOHUTUS HOIATUS See vahend ja seotud seadmed võivad sisaldada akusid ja muid keskkonnaohtlikke materjale.
  • Page 10 HOIATUS Kui GlideScope Core’i tööjaam Premium on varustatud GlideScope Core’i 15‑tollise monitoriga, võib tööjaam mõnes pikendatud asendis ümber kukkuda ja vigastusi põhjustada. Selle vältimiseks liigutage monitor enne süsteemi veeretamist kõige madalamasse ja kõige tagasitõmmatumasse asendisse.
  • Page 11 Rakendage töö ajal vajalikke ettevaatusabinõusid. ETTEVAATUST Süsteem sisaldab elektroonilisi osi, mida ultraheliseade ja automaatne pesur võivad kahjustada. Ärge kasutage toote puhastamiseks ultraheliseadet ega automaatset pesurit, mida Verathon ei ole heaks kiitnud. ETTEVAATUST Veenduge, et te ei kasutaks videomonitori ekraani puhastamisel abrasiivseid harju, patju ega tööriistu.
  • Page 12: Introduction

    Titanium video laryngoscopes must be cleaned and high‑level disinfected between uses. These connect to the video monitor through the reusable GlideScope Core Video Cable. Due to their titanium construction, reusable video laryngoscopes contain a T in the blade name, such as LoPro T4.
  • Page 13: System Parts & Accessories

    SYSTEM PARTS & ACCESSORIES Table 1. Required System Components REQUIRED PARTS & ACCESSORIES GlideScope Core video monitor GlideScope Core 10 GlideScope Core 15 12V DC power adapter Power cable Video cable* †‡ One or more of the following scope styles: Spectrum Single‑Use Blades Video Batons and Single‑Use Stats...
  • Page 14: Buttons, Icons, & Connections

    Oximeter BUTTONS, ICONS, & CONNECTIONS The digital, full‑color GlideScope Core Video Monitor clearly displays the images transmitted from the camera in the scope. The front of the monitor includes the button for power and the touchscreen. The back panel of the monitor includes sockets and ports for connecting the power cord, video cables, USB flash drives, and an HDMI cable for an external video display.
  • Page 15 Table 3. Monitor Buttons BUTTON GROUP BUTTON FUNCTION Power: This is a physical button located on the bottom left corner of the display. Press and release to turn on the monitor. Press and hold to turn it off. Front panel Note: If the monitor locks up or becomes unresponsive for any reason, press and hold the Power button for 7 seconds to turn off the system.
  • Page 16 BUTTON GROUP BUTTON FUNCTION Switch in the off position. Toggle switches Switch in the on position. Note: If the toggle switch enables the Video Rotation option, it turns gold. Video Layout Menu: Opens the Video Layout menu. The menu contains several selectable layout configurations.
  • Page 17 BUTTON GROUP BUTTON FUNCTION Save: Saves editor changes. Note editor Close: Closes editor. Copy: After tapping the Export button, select this option to copy the selected files to the USB drive. This leaves a copy in the internal memory. Media Export Move: After pressing the Export button, select this option to move the selected files to the USB drive.
  • Page 18 ICON FUNCTION Internal Memory: Displays available internal memory. USB Drive: Displays available USB memory. Shows when a USB drive is attached. Attention: Indicates important text. USB Flash Drive: Indicates a USB flash drive is detected. Hourglass: Advises the operator to wait while the system shuts down. Patient name field: Indicates the patient name text entry field.
  • Page 19 Figure 1. GlideScope Core Monitor Front Panel Battery indicator LED: Displays power and battery charge state LCD touch screen: Displays images from video accessories and recorded videos and Power button: images Powers the monitor on or off Figure 2. GlideScope Core Monitor Back Panel...
  • Page 20: System Features

    Note: If a pulse oximeter is attached to the monitor and is not receiving information from a patient, two dashes (‑‑) are shown instead of a reading. * GlideScope Core 15 Dual View layout pictured. † Only shown when two cameras are connected to monitor.
  • Page 21: Gallery

    IMPORTANT The SpO values displayed on the monitor can be used as a convenient secondary display. These are not intended for patient diagnosis. For direction on using the USB pulse oximeter, please refer to the Nonin instructions for use. RIGHT BAR The right bar displays an icon for connected scopes.
  • Page 22: Setting Up

    1. Verify that you have received the appropriate components for your system by referring to the packing list included with the system. 2. Inspect the components for damage. 3. If any of the components are missing or damaged, notify the carrier and Verathon Customer Care or your local representative. For contact information, visit verathon.com/global‑support. 0900‑5017‑ETEE REV‑05...
  • Page 23: Procedure 2. Mount The System (Optional)

    MOUNT THE SYSTEM (OPTIONAL) If you choose to mount the system, the GlideScope Core Premium Workstation makes it easy for you to move the system from one location to another, and to adjust the monitor’s position to fit your needs.
  • Page 24 ATTAcH THE MONITOR TO THE WORKSTATION 1. Assemble the workstation according to its included instructions. 2. When attaching the quick‑release locking plate, ensure the (4) screws are fully tightened and the locking plate is securely attached to the monitor. Note: The screws and hex driver are included with the workstation. 3.
  • Page 25 ADJUST THE MONITOR TILT ANGLE TENSION If the angle of the monitor is difficult to adjust, or the monitor angle tilts down on its own, the workstation’s monitor angle tension needs to be adjusted. • Using a 4 mm hex wrench, turn the tension adjustment screw clockwise to increase the tension, or counter‑clockwise to decrease it.
  • Page 26: Procedure 3. Charge The Monitor Battery

    Hoiatused ja ettevaatusabinõud section before performing the following task. The GlideScope Core Monitor includes an internal lithium battery. Verathon recommends that you charge the battery fully prior to first use. Under normal operating conditions, a fully charged battery lasts approximately 135 minutes for Core 10, and 90 minutes for Core 15 before it needs to be recharged.
  • Page 27: Procedure 4. Complete The Setup Wizard (Optional)

    PROcEDURE 4. cOMPLETE THE SETUP WIZARD (OPTIONAL) The first time the monitor is powered on, a setup wizard guides you through some initial settings. If the setup wizard has already been completed, or you decide to skip the setup wizard, all settings can be modified in Configure User Settings (Optional) on page 25.
  • Page 28 2. Set the date and date format, and then tap the check mark to continue. 3. Set the time, time zone, and the daylight saving preference, and then tap the check mark to continue. 0900‑5017‑ETEE REV‑05...
  • Page 29 1 minute 5 minutes 10 minutes 20 minutes 30 minutes * If the security code has been forgotten, please contact Verathon Customer Care. For contact information, visit verathon.com/global‑support. Operations & Maintenance Manual: Setting Up 0900‑5017‑ETEE REV‑05...
  • Page 30 6. Enter a name for the monitor to help identify it. If a name is not needed, tap the check mark to proceed to the confirmation window. 7. When the settings wizard is done, tap the check mark to return to the Home screen. 8.
  • Page 31: Procedure 5. Configure User Settings (Optional)

    PROcEDURE 5. cONFIGURE USER SETTINGS (OPTIONAL) The Settings menu allows you to configure, change, or view the following system settings and information: Feature Settings Tab • System Sounds • Snapshot • Microphone • Brightness and Contrast • Snapshot Timestamps • Video Timestamps •...
  • Page 32 Table 5. Feature Settings SETTING FUNCTION Toggles whether sound effects are heard when buttons are pressed. When on, provides options for all systems sounds, or alerts on ly. 10:55 AM CITY HOSPITAL 2017-06-05 When the System Sounds are toggled on, tap the System Sounds Video Rotation Speaker...
  • Page 33 REGIONAL SETTINGS TAB Use the Regional Settings tab to choose the date, date format, time, time format, daylight saving time, and time zone settings. 1. To access the Regional Settings tab, from the Home screen, tap the Main Menu button, and then tap the Settings button.
  • Page 34 Displays software versions for various system resources. Reset Settings Restores all settings back to factory defaults. * If the security code has been forgotten, please contact Verathon Customer Care to request a security code reset USB flash drive. For contact information, visit verathon.com/global‑support...
  • Page 35: Procedure 6. Attach The Video Cable And Scope

    This procedure provides basic instruction on connecting compatible video cables and scopes to the monitor. For detailed information about cables and scopes, refer to one of the following manuals or contact Verathon Customer Care: •...
  • Page 36 The cable disconnects from the monitor. OptiOn 1. GLiDESCOpE CORE ViDEO CABLE 1. Bring into line the alignment marks on the video cable and scope connectors, and then fully insert the video cable into the scope connector port. You will hear a click when the cable is successfully connected.
  • Page 37: Procedure 7. Attach The Usb Device (Optional)

    PROcEDURE 7. ATTAcH THE USB DEVIcE (OPTIONAL) Connecting a USB drive to one of the USB ports allows you to export exams that were saved to the internal memory. The ports also allows a Nonin 3231 USB External Pulse Oximeter to be attached. The SpO reading from the sensor is shown on the Core display for convenience, but should not be used for diagnostic purposes.
  • Page 38: Procedure 8. Connect To An External Monitor (Optional)

    IMPORTANT To maintain electromagnetic interference (EMI) within certified limits, the system must be used with the cables, components, and accessories specified or supplied by Verathon. For additional information, see the System Parts & Accessories Component Specifications sections.
  • Page 39: Procedure 9. Perform A Functional Check

    PERFORM A FUNcTIONAL cHEcK Before you use the device for the first time, perform the following functional check to ensure that the system is working properly. Please contact your Verathon Customer Care representative if your system does not function as described below.
  • Page 40: Using The Device

    USING THE DEVICE Prior to using the device, set up the device according to the instructions in the previous chapter, and verify the setup by completing Step 1 through Step 4 of the procedure Perform a Functional Check on page 33. Please read the Hoiatused ja ettevaatusabinõud section before performing the following tasks.
  • Page 41: Procedure 2. Use A Usb Pulse Oximeter

    For direction on using the USB pulse oximeter, please refer to the Nonin instructions for use. CITY HOSPITAL The GlideScope Core monitor is compatible with the Nonin 3231 USB External Pulse Oximeter. When connected, the SpO and pulse rate can be found in the upper left corner of the display.
  • Page 42: Procedure 3. Adjust Video Layout

    PROcEDURE 3. ADJUST VIDEO LAYOUT When the monitor has two scopes connected, a video layout menu is available. This menu allows you to select how the video feeds are displayed. Attached scopes Video layout menu (updates to match the current layout) 1.
  • Page 43: Procedure 4. Rotate The Display

    PROcEDURE 4. ROTATE THE DISPLAY The display can be rotated 180 degrees if needed. The option to show the video rotation button can be turned on or off in the user settings. To change this setting, see Configure User Settings (Optional) on page 25.
  • Page 44: Procedure 6. Use The Gallery

    2. When you are finished recording, press the Record button again. The recording stops. 3. If you would like to save a photo of the live display, press the Snapshot button. A frame briefly appears around the video to indicate the snapshot has been taken. This can also be done while the recording video.
  • Page 45 2. To select all the files in a row, tap the Select All check box to the left of the row. 018-05-22 10:29 2018-05-22 10:29 6:13 6:13 018-06-01 8:10 2018-06-01 8:10 FAVORITES 0:48 0:48 1. To mark a file as a favorite, tap the check box to select the file(s), and then tap the Favorite button in the left bar.
  • Page 46 2. Connect the USB flash drive to the one of the USB ports. USB ports 3. Ensure that the USB flash drive is detected by verifying the USB icon is visible at the top of the screen. 4. From the Home screen, tap the Main Menu button, and then tap the Gallery button.
  • Page 47 VIEWING MEDIA If you would like to export, delete, or favorite a file being viewed, tap the check box at the upper left corner of the file thumbnail, and then tap the corresponding button on the left of the display. 10:55 CITY HOSPITAL 2018-10-14...
  • Page 48 VIEW A SNAPSHOT 11. To review a recorded snapshot, tap its thumbnail. The Photo Viewer opens. 10:55 AM CITY HOSPITAL 2017-06-05 95 min 2016-01-06 6:16 AM Internal Storage USB Drive 0:27 2017-03-15 1:44 PM 2017-05-22 10:29 AM VIEW PATIENT NOTES 12.
  • Page 49: Reprocessing

    For information about the cleaning, disinfection, and sterilization requirements for these components, refer to the GlideScope and GlideRite Products Reprocessing Manual, which is available at verathon.com/product‑documentation. Operations & Maintenance Manual: Reprocessing 0900‑5017‑ETEE REV‑05...
  • Page 50: Hooldus Ja Ohutus

    Verathoni klienditeeninduse esindajalt. SÜSTEEMI TARKVARA Verathon võib välja anda videomonitori tarkvaravärskendusi. Tarkvaravärskendusi pakub Verathon või Verathoni volitatud esindaja ning värskendusega on kaasas ka paigaldamisjuhised. Selles juhendis on kirjeldatud dokumendi koostamise ajal saadaolevat uusimat tarkvaraversiooni. Kui monitor ei tööta selles juhendis kirjeldatud viisil või soovite kindlaks teha, kas tarkvara tuleks värskendada, võtke...
  • Page 51: Seadme Parandamine

    SEADME PARANDAMINE GlideScope Core’i komponendid ei ole kasutajate hooldatavad. Verathon ei avalda ühtegi elektriskeemi, komponentide ja osade loendit, kirjeldust ega muud teavet, mida oleks vaja seadme ja selle tarvikute parandamiseks. Kõik hooldustööd peab tegema kvalifitseeritud tehnik. Kui teil on küsimusi, võtke ühendust Verathoni kohaliku esindaja või Verathoni klienditeenindusega.
  • Page 52: Limited Warranty

    Product to Verathon (cleaned and disinfected as appropriate) immediately upon receiving the loaner unit from Verathon. Buyer shall return the loaner unit within two (2) business days of receipt of the repaired or replaced Product. All exchanged parts become property of Verathon.
  • Page 53 European Customers, any terms herein limiting Verathon’s liability shall not apply insofar as they conflict with mandatory statutory provisions of the Product Liability Act.
  • Page 54: Product Specifications

    PRODUCT SPECIFICATIONS COMPONENT SPECIFICATIONS VIDEO MONITOR SPECIFICATIONS Table 8. Core 10 (0570‑0376) GENERAL SPECIFICATIONS Classification: Electrical Class II, Applied Part BF Range: 100–240 V AC, 50 and 60 Hz Line voltage: (If the power cord has a third prong, the third conductor is not intended to be a protective earth connection for the medical power supply.) DC power supply: 12 V DC, 2.5 A max...
  • Page 55 Table 9. Core 15 (0570‑0404) GENERAL SPECIFICATIONS Classification: Electrical Class II, Applied Part BF Range: 100–240 V AC, 50 and 60 Hz Line voltage: (If the power cord has a third prong, the third conductor is not intended to be a protective earth connection for the medical power supply.) DC power supply: 12 V DC, 2.5 A max Ingress protection:...
  • Page 56 WORKSTATIONS Table 10. Premium Workstation (0800‑0636) COMPONENT SPECIFICATIONS Wheelbase diameter (A) 64 cm Min. height (B) 142 cm ± 2 cm B–C Max. height (C) 165 cm ± 2 cm Safe working load 42 kg Table 11. Premium Workstation (0800‑0557) COMPONENT SPECIFICATIONS Wheelbase diameter (A) 64 cm Min.
  • Page 57 ELECTROMAGNETIC COMPATIBILITY The system is designed to be in compliance with IEC 60601‑1‑2, which contains electromagnetic compatibility (EMC) requirements for medical electrical equipment. The limits for emissions and immunity specified in this standard are designed to provide reasonable protection against harmful interference in a typical medical installation.
  • Page 58 Table 13. Guidance and Manufacturer’s Declaration —Electromagnetic Immunity The system is intended for use in the electromagnetic environment specified below. The customer or the user of the system should ensure that it is used in such an environment. COMPLIANCE ELECTROMAGNETIC ENVIRONMENT IMMUNITY TESTS IEC 60601 TEST LEVEL LEVEL...
  • Page 59 Table 13. Guidance and Manufacturer’s Declaration —Electromagnetic Immunity The system is intended for use in the electromagnetic environment specified below. The customer or the user of the system should ensure that it is used in such an environment. COMPLIANCE ELECTROMAGNETIC ENVIRONMENT IMMUNITY TESTS IEC 60601 TEST LEVEL LEVEL...
  • Page 60 ACCESSORY CONFORMANCE TO STANDARDS To maintain electromagnetic interference (EMI) within certified limits, the system must be used with the cables, components, and accessories specified or supplied by Verathon. For additional information, see the System Parts & Accessories Component Specifications sections.
  • Page 61: Glossary

    The following table provides definitions for specialized terms used in this manual or on the product itself. For a full list of caution, warning, and informational symbols used on this and other Verathon products, please refer to the Verathon Symbol Glossary at verathon.com/symbols.
  • Page 62 TERM DEFINITION OSHA Occupational Safety and Health Administration (federal agency in U.S.) psia Pounds per square inch absolute Water that is suitable for high‑level disinfection according to local regulations Pure water and your medical facility Radio frequency Relative humidity Restriction of the Use of Certain Hazardous Substances in Electrical and RoHS Electronic Equipment Sodium dodecyl sulphate...