Download Print this page

Cal-Royal CR3000 Owner's Manual page 3

Digital electronic lock

Advertisement

Connections:
Batteries:
Use only 1.5 volt AA batteries, 4 pieces.
Low Battery:
RED LED will flash five times with beep sound before BLUE LED flashes to signify acceptance of code. Batteries should be replaced as soon as
this happens.
Remote Switch/Release Options:
The unit has 2 sets of terminals for remote release, labeled REM1 and REM2 on the printed circuit board.
REM1 can be connected to a push button. Pushing the button will cause the unit to unlock. The BLUE LED will light and at the same time a beep
can be heard twice.
REM2 is intended for alarm systems such as fire alarms. When activated the unit will stay unlocked for 30 minutes and RED LED will flash once
every 2 seconds while an audible alarm sound will be heard indicating that the unit is in the unlocked condition.
The lock will automatically revert to normal after 30 minutes. If necessary, the Master Code, Sub-Master Code or Manager Code can be
programmed to revert the unit to normal before the 30-minute period ends.
Initial Setup:
1.
Remove batteries. Press and hold (#) while connecting the batteries back.
Release after hearing 5 beeps. Within 3 seconds, press (#) keypad 3 times. The BLUE LED will continuously light for 3 seconds and 2
beeps will be heard.
2.
The unit is now clear of all programmed data and will have reverted to the factory default Master Code 12345.
NOTE: Please follow procedures above exactly otherwise unit will function abnormally. In this case, please repeat the procedure.
No other programming commands will be accepted until default Master Code has been changed.
Codes:
Codes may be 3, 4 or 5 digits long. The length of the Master Code determines all the codes format.
Once the numbers of digits are selected, it cannot be changes unless all programming is erased and the default factory settings are re-
loaded.
No other programming commands will be accepted until default Master Code has been changed.
MASTER CODE and SUB-MASTER CODE
This unit is delivered with the Master Code set to 12345 (default).
The Master Code cannot be deleted.
Master Code performs all programming functions.
Sub-Master Code performs all programming functions except delete or change Master code.
MANAGERS CODE
All Managers Code location ends in zero. (00, 10, 20, 30, 40, 50, 60, 70, 80, 90)
Manager Codes are capable of programming and deleting user codes under his Bank. Managers are also capable of accessing the
next higher Bank until another Manager Code appears.
USER CODES
Does not have programming privileges. Codes are used for entry only.
SERVICE CODES
Service Codes are one-time codes only. It cannot be used again. Once a service code is entered, the unit will unlock but it will
automatically delete the code.
VALID CODES and PASS TIME (DOOR UNLOCK)
Pass Time is the time the unit is unlocked after a valid code is entered.
BLUE LED will flash (with 2 beeps) after a valid code is entered.
Pass Time also determines the amount of time between two key presses. If the succeeding entry (or key press) was pressed after the
Pass Time, it is now considered as a new entry. Should this happen, wait 5 seconds for the unit to reset by itself then try entering the
code again.
INVALID CODES
The RED LED will flash for .5 seconds with one beep after an invalid code is entered