Pilz PNOZ X8P Operating Manual page 31

Safety relays
Table of Contents

Advertisement

PNOZ X8P
Relay outputs
External contact fuse protection,
safety contacts
In accordance with the standard EN 60947-5-1
Max. melting integral
Blow-out fuse, quick
Blow-out fuse, slow
Blow-out fuse, gG
Circuit breaker 24V AC/DC,
characteristic B/C
External contact fuse protection,
auxiliary contacts
Max. melting integral
Blow-out fuse, quick
Blow-out fuse, slow
Blow-out fuse, gG
Circuit breaker 24 V AC/DC,
characteristic B/C
Contact material
Conventional thermal current
while loading several contacts
Ith per contact at UB AC;
AC1: 240 V, DC1: 24 V
Conv. therm. current with 1 con-
tact
Conv. therm. current with 2 con-
tacts
Conv. therm. current with 3 con-
tacts
Times
Switch-on delay
With automatic start typ.
With automatic start max.
With automatic start after power
on typ.
With automatic start after power
on max.
With manual start typ.
With manual start max.
With monitored start typ.
With monitored start max.
Delay-on de-energisation
With E-STOP typ.
With E-STOP max.
With power failure typ.
With power failure max.
Operating Manual PNOZ X8P
19820-EN-10
787768
240 A²s
10 A
6 A
10 A
6 A
240 A²s
10 A
6 A
10 A
6 A
AgSnO2 + 0,2 µm Au
787768
8 A
7,3 A
6 A
787768
175 ms
220 ms
200 ms
250 ms
190 ms
250 ms
130 ms
180 ms
15 ms
30 ms
160 ms
220 ms
787770
EN 60947-5-1
240 A²s
10 A
6 A
10 A
6 A
240 A²s
10 A
6 A
10 A
6 A
AgSnO2 + 0,2 µm Au
787770
8 A
7,3 A
6 A
787770
175 ms
220 ms
200 ms
250 ms
190 ms
250 ms
130 ms
180 ms
15 ms
30 ms
160 ms
220 ms
| 31