Pilz PNOZ X8P Operating Manual page 20

Safety relays
Table of Contents

Advertisement

PNOZ X8P
Relay outputs
Utilisation category of
safety contacts
AC1 at
Min. current
Max. current
Max. power
DC1 at
Min. current
Max. current
Max. power
Utilisation category of
auxiliary contacts
AC1 at
Min. current
Max. current
Max. power
DC1 at
Min. current
Max. current
Max. power
Utilisation category
In accordance with the
standard
Utilisation category of
safety contacts
AC15 at
Max. current
DC13 (6 cycles/min) at 24 V
Max. current
Utilisation category of
auxiliary contacts
AC15 at
Max. current
DC13 (6 cycles/min) at 24 V
Max. current
Utilisation category in ac-
cordance with UL
Voltage
With current
Voltage
With current
Pilot Duty
Operating Manual PNOZ X8P
19820-EN-10
777760
240 V
0,01 A
8 A
2000 VA
24 V
0,01 A
8 A
200 W
240 V
0,01 A
8 A
2000 VA
24 V
0,01 A
8 A
200 W
EN 60947-5-1
230 V
5 A
7 A
230 V
5 A
7 A
240 V AC G. P.
8 A
24 V DC Resistive
5 A
B300, R300
777764
240 V
0,01 A
8 A
2000 VA
24 V
0,01 A
8 A
200 W
240 V
0,01 A
8 A
2000 VA
24 V
0,01 A
8 A
200 W
EN 60947-5-1
230 V
5 A
24 V
7 A
230 V
5 A
24 V
7 A
240 V AC G. P.
8 A
24 V DC Resistive
5 A
B300, R300
777768
240 V
0,01 A
8 A
2000 VA
24 V
0,01 A
8 A
200 W
240 V
0,01 A
8 A
2000 VA
24 V
0,01 A
8 A
200 W
EN 60947-5-1
230 V
5 A
24 V
7 A
230 V
5 A
24 V
7 A
240 V AC G. P.
8 A
24 V DC Resistive
5 A
B300, R300
| 20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents