PNOZ X8P
Electrical data
Supply voltage
Voltage
Kind
Voltage tolerance
Output of external power supply
(AC)
Frequency range AC
Duty cycle
Inputs
Number
Voltage at
Input circuit DC
Start circuit DC
Feedback loop DC
Current at
Input circuit DC
Start circuit DC
Feedback loop DC
Min. input resistance at power-on
Max. overall cable resistance Rl-
max
Single-channel at UB AC
Dual-channel without detection
of shorts across contacts at UB
AC
Dual-channel with detection of
shorts across contacts at UB AC 28 Ohm
Semiconductor outputs
Number
Voltage
Current
External supply voltage
Voltage tolerance
Residual current at "0" signal
Max. internal voltage drop
Conditional rated short circuit cur-
rent
Lowest operating current
Utilisation category in accordance
with EN 60947-1
Relay outputs
Number of output contacts
Safety contacts (N/O), instant-
aneous
Auxiliary contacts (N/C)
Max. short circuit current IK
Operating Manual PNOZ X8P
19820-EN-10
787768
230 V
AC
-15 %/+10 %
6,5 VA
50 - 60 Hz
100 %
787768
2
24 V
24 V
24 V
40 mA
60 mA
60 mA
89 Ohm
100 Ohm
200 Ohm
787768
2
24 V
50 mA
24 V
-20 %/+20 %
0,1 mA
4 V
100 A
0 mA
DC-12
787768
3
2
1 kA
787770
24 V
AC
-15 %/+10 %
6,5 VA
50 - 60 Hz
100 %
787770
2
24 V
24 V
24 V
40 mA
60 mA
60 mA
89 Ohm
100 Ohm
200 Ohm
28 Ohm
787770
2
24 V
50 mA
24 V
-20 %/+20 %
0,1 mA
4 V
100 A
0 mA
DC-12
787770
3
2
1 kA
| 29