Safety Cable Installation - Monte Carlo Fan Company 3MNLR72 D Series Owner's Manual And Installation Manual

Table of Contents

Advertisement

1
Before you begin installing the fan, Switch
power off at Service panel and lock
service disconnecting means to prevent
power from being switched on
accidentally. When the service
disconnecting means cannot be locked,
securely fasten a warning device, such
as a tag, to the service panel.
Use AC 120V/60HZ power supply
only.

SAFETY CABLE INSTALLATION

4
Safety cable
Lag screw
Safety cable
Washer
Lock washer
For Canadian installation and for USA fan
and light kit combinations over 35 lbs, in
both flush and downrod modes the safety
cable must be installed into the house
structure beams using 1.5" lag screws,
washers and lock washers provided.
Note
: If Installing The Secondary Support
Safety Cable in the U.S., Do Not Remove
Knockouts In The Outlet Box.
© 2014 Monte Carlo Fan Company
2
Ceiling
Ceiling
Joists
Before installing this fan makes sure the
outlet box is properly installed to the
house structure. Ensure the outlet box is
securely fastened by at least two points
to a structural ceiling member (a loose
box will cause the fan to wobble).
To reduce the risk of fire, electric shock,
or personal injury, mount to outlet box or
supporting system acceptable for fan
support.
(Mounting must support at least 35 lbs.)
5
Junction
Box
LED light kit
Mounting
Bracket
Place fan assembly on styrofoam to keep
the LED light kit away from damage and
make fan installation easier.
Flip the bottom styrofoam over, aligning
the part of the LED light kit with the hole
in the styrofoam and then place the fan
assembly on it for fan installation.
3
2˝ x 4˝
Outlet
Box
Partially loosen 2 of the set screws on
mounting bracket corresponding to the slotted
holes on the canopy upper ring. Remove the
other 2 set screws. Save screws.
Use metal outlet box suitable for fan
support and use only the screws provided
with the outlet box (must support 35
lbs). Remove the two outlet box screws
provided with the box, aligning the holes
of the mounting bracket with the holes of
the outlet box. Reinstall the 2 outlet box
screws securely.
6
Partially loosen downrod set screws from
yoke at top of motor assembly.
Remove preassembled cross pin and
keeper pin from downrod.
3
Ceiling joist
Outlet Box
Mounting
Bracket
Screw/ Washers
/Spring Washers
Keeper pin
Fan Wiring
Yoke
Downrod
Cross
pin
11/1/2014

Advertisement

Table of Contents
loading

This manual is also suitable for:

3mnlr72

Table of Contents