Louver Control; Louver Position - Toshiba RAS-M10PKVPG-E Service Manual

Hide thumbs Also See for RAS-M10PKVPG-E:
Table of Contents

Advertisement

Item

7. Louver control

This function controls the air direction of the indoor unit.
1) Louver
• The position is automatically controlled according to the operation
position
mode (COOL/HEAT).
• The set louver position is stored in memory by the microcomputer,
and the louver returns to the stored position when the next operation
is performed. (Cooling/Heating memory position)
The angle of the louver is indicated as the louver closes fully is 0°.
1) Louver position in cooling operation
Manual and automatic operation
Initial setting is directs downward (20mm)
Wide-angle
Left side lover setting is left facing (75mm)
Right side lover setting is right facing (75mm)
Spot front
Left side lover setting is left facing (55mm)
Right side lover setting is right facing (55mm)
Operation flow and applicable data, etc.
HI-POWER operation
Default setting is directs downward (45mm)
Wide air direction
Wide position is directs downward (20mm)
Right wide
Left side lover setting is front facing (55mm)
Right side lover setting is right facing (75mm)
Spot air direction
Wide position is directs downward (73mm)
Spot right
Left side lover setting is front facing (35mm)
Right side lover setting is right facing (75mm)
- 31 -
FILE NO. SVM-18047
Description
Left wide
Left side lover setting is left facing (75mm)
Right side lover setting is front facing (55mm)
Spot left
Left side lover setting is left facing (75mm)
Right side lover setting is front facing (35mm)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ras-m13pkvpg-eRas-m16pkvpg-e

Table of Contents