PRECAUTIONS FOR SAFETY • Keep this manual where the operator can easily find it. • Read the precautions in this manual carefully before operating the unit. • This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons. • The precautions described herein are classified as DANGER, WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail. DANGER • Do not install, repair, open or remove the cover. It may expose you to dangerous voltages. Ask the dealer or the specialist to do this. • Turning off the power supply will not prevent potential electric shock. • The appliance shall be installed in accordance with national wiring regulation. • Means for disconnection from the supply having a contact separation of at least 3 mm in all poles must be incorporated in the fixed wiring. • The appliance must be stored in a room without continuously operating ignition sources (for example, open flames an operating gas appliance or an operating electric heater). • In order to avoid fire explosion or injury, do not operate the unit when harmful gases (e.g. flammable or corrosive) are detected near the unit. WARNING • Do not expose your body directly to cool air for a long time. • Do not insert your finger or any article into the air inlet/outlet. • When an abnormality (burning smell, etc.) occurs, stop the air conditioner and disconnect the power supply or turn off the breaker. • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the...
Page 3
PRECAUTIONS FOR SAFETY • Do not use any refrigerant different from the one specified (R410A) for complement or replacement. Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or an injury to your body. • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. • The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater). • Be aware that refrigerants may not contain an odour. • Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to heat, flames sparks, or other sources or ignition. Else, it may explode and cause injury or death. CAUTION • Do not wash the unit with water. It may cause an electric shock. • Do not use this air conditioner for other purposes such as preserving food, breeding animal, etc. • Do not step or put anything on the indoor/outdoor unit. It may cause an injury or damage the unit. • Do not touch aluminium fin because it may cause an injury. • Before cleaning the unit, turn off the main switch or the circuit breaker. • When the unit won’t be used for a long time, turn off the main switch or the circuit breaker. • It is recommended that maintenance be performed by a specialist when the unit has been operated for a long time. • The manufacturer shall not assume any liability for the damage caused by not observing the description of this manual.
INDOOR UNIT DISPLAY ONE-TOUCH Press the “ONE-TOUCH” button for fully automated operation that is customized 1 ECO (White) to the typical consumer preferenced in your region of the world.The customized 2 Wi-Fi access (White) settings control temperature air flow strength, air flow direction and other settings 3 Hi Power (White) to provide you alternate contact with 4 Timer (White) “ONE-TOUCH” of the button. If you prefer other settings you can select from the 5 Operation (White) many other operating functions of your Toshiba unit. Press : Start the operation. ● Display brightness can be adjusted, follow procedure on @. AUTOMATIC OPERATION Require Wireless LAN connecting adapter which available as accessory. PREPARATION BEFORE USE To automatically select cooling,or fan only operation 1. Press : Select Auto A. Preparing Filters 1. Open the air inlet grille and remove the air filters. 2. Press : Set the desired temperature, Min. 17°C, Max. 30°C. 2. Attach the filters. (see detail in the Installation manual).
Page 5
SELF CLEANING OPEATION DISPLAY LAMP BRIGHTNESS ADJUSTMENT (COOL AND DRY OPEATION ONLY) To decrease the display lamp brightness or turn it off. To protect bad smell caused by the humidity in the indoor unit. 1. Press and hold for 3 seconds until brightness level ( ) is shown on remote control LCD then release the button. 1. If the button is pressed once during “Cool” or “Dry” mode, the fan will continue to run for other 30 minutes, then it will turn off 2. Press to adjust brightness in 4 levels. Rise automatically. This will reduce the moisture in the indoor unit. Decrease 2. To stop the unit immediately, press the more 2 times Remote control within 30 seconds. Operation display Brightness MAINTENANCE 100% Lamp illuminates full brightness. Firstly, turn off the circuit breaker. Indoor Unit and Remote Control ●...