10-4. Electrical works
Model
Power source
Maximum running current
Circuit breaker rating
Power supply cable
Connecting cable
* Refer to service manual of the outdoor unit which combined.
10-4-1. Wiring Connection
Indoor unit
Wiring of the cable can be carried out without removing the main panel.
1. Remove the front panel.
Pull and lift up front panel until it stops, move arms on left and right side
to outward direction then pull toward you to remove front panel.
Beware front panel fall down that may cause of injure or part damage.
Arm
Fig. 10-4-1
2. Remove the terminal cover and cord clamp.
3. Insert the cable (according to the local cords) into the pipe hole on the
wall.
4. Take out the cable protrudes about 20 cm from the front.
5. Insert the cable fully into the terminal block and secure it tightly with
screws.
6. Tightening torque : 1.2 N·m (0.12 kgf·m)
7. Secure the cable with the cord clamp.
8. Fix the terminal cover and attach front panel to the indoor unit.
Front panel
Cable
Fig. 10-4-2
How to attach the front panel
Carry out attaching in the reverse order to removal.
Keep front panel horizontally and put both arms into guides.
Make sure both arms are inserted completely.
If the gap between main panel and front panel isn't even, remove and
attach again.
RAS-M10PKVPG-E
RAS-M13PKVPG-E
50Hz, 220 – 240 V Single phase
*
*
H07RN-F or 60245 IEC66 (1.5 mm
Arm
Terminals block
Main panel
Terminal cover
RAS-M16PKVPG-E
*
*
*
*
2
or more)
• Be sure to refer to the wiring system diagram labeled inside the
main panel.
• Check local electrical cords and also any specifi c wiring instructions or
limitations.