OPERATING INSTRUCTIONS

Only qualified or trained personnel should use this appliance.
Do not place metal objects, aluminium foil and plastic vessels on the ceramic glass
surface, and do not use the surface for storage.
Rings, watches and similar objects could get hot when in close proximity to the hob
surface.
Users with heart pacemakers should consult with the manufacturer of the
pacemaker or their doctor.
Information
With induction cooking, heat is produced directly in the base of the pan. The
system comprises a ceramic glass hob surface with an induction coil beneath,
which generates an alternating magnetic field. When a pan with a magnetic base is
placed on the cooking zone, eddy currents are created in the pan base leading to
the production of heat. The pan heats quickly. The quality of the cookware is
important to the efficiency of induction cooking.
On flat hobs, the pan base must be flat with good heat distribution.
On wok hobs, the pan profile should closely match the shape of the glass.
Generally, suitable pans are made from cast iron, enamelled steel and stainless
steel with a magnetic base. Unsuitable pans are glass, earthenware, aluminium,
copper and non-magnetic stainless steel. Use pans of the size and type
recommended.
Operation of the pan detection system is dependent on the size of the pan and its
material.
Recommended pan base diameters – SLI21, SLI3, SLI42
Minimum pan
Limit of detection
Nominal coil diameter
The pan should be located concentrically over the glass target ring. If the inner ring
of the ceramic glass is visible around the pan, the pan is too small.
It is normal for induction generators to make buzzing, whistling and clicking noises,
especially on lower power settings.
If the ceramic glass surface is cracked, immediately disconnect the appliance
from the supply.
Connect to the mains supply and switch on. The green neon will illuminate and the
cooling fan will begin operating. (SLI42 has two supply cords and two neons).
IS 564 ECN 3766
Rear zone
180mm
135mm
210mm
Page 7 of 13
Front zone
120mm
90mm
145mm