Silverlink induction hobs need cool air to operate satisfactorily.
The cooling air is drawn in through the air filter in the base of the unit; and hot air is
exhausted through the back panel.
It is important that hot exhaust air cannot be drawn back into the inlet filter, as this
recirculation will degrade the performance of the induction system, leading to an
overheat shutdown.
Exhaust minimum clearance to any partitions, walls or furniture; C=100mm.
C
AIR
AIR
Floor stands:
The SLI21, SLI3, SLI3W may be mounted on a Lincat CC4 ambient pedestal or
SLS4 stand.
The SLI42 may be mounted on a Lincat CC6 ambient pedestal or SLS6 stand.
Refer also to page 12.
These units are not suitable to mount on the HC4/HC6/HCL4/HCL6 heated
pedestals, or on top of V6/V7 ovens.
IS 564 ECN 3766
Page 6 of 13