TROUBLESHOOTING

The fan does not start
when the unit is turned on.
Switch is automatically
activated after turning on.
Insufficient air flow

TRANSPORTATION AND STORAGE

The intake-extractor unit must be put in the original packaging in a ventilated area at a temperature
ranging between +10°C and +40°C.
The air must not contain potentially aggressive vapours or chemical mixtures that might cause
corrosion or compromise the integrity of the connections.
For handling, use only adequate lifting equipment, in order to prevent damage to the fan following
falls or excessive shaking. Follow the applicable regulations for transportation according to the
type of load.
The intake-extractor unit can be transported with any means, provided that adequate protection
against atmospheric agents and mechanical damages is ensured.
Avoid jolts and collisions during transportation and handling operations.
Possible causes
No power supply.
The motor is blocked, the
impeller is blocked.
Overcurrent due to
a short-circuit in the
electrical circuit.
Speed set low.
The filter, the fan or the
exchanger are dirty.
Management of faults
Check that the unit is correctly
connected to the mains supply
and connect it, if necessary.
Turn off the recovery unit. Find
the cause of the motor blockage
and unblock the fan. Clean the
blades. Restart the fan.
Turn off and contact customer
service.
Set a higher speed.
Clean or replace the filter. For
filter maintenance, please refer
to page 16.