Page 2
This document introduces the specifications of Baicells EG7010A-M11 CPE and guides users to install and configure it. Copyright Notice Baicells copyrights this specification. No part of this specification may be reproduced in any form or means, without the prior written consent of Baicells. Disclaimer This specification is preliminary and is subject to change at any time without notice.
-users. Features The EG7010A-M11 is designed according to the simplicity principle, which can evolve in a short period and realize fast customization, delivery and deployment as well. The main features of the EG7010A-M11 is as follows: ...
Figure 1-1 EG7010A-M11 Appearance The EG7010A-M11 interfaces and buttons are shown in Figure 1-2. Figure 1-2 Interface and Button of EG7010A-M11 The EG7010A-M11 interface and button description is given in Table 1-1. Table 1-1 Description of EG7010A-M11 Interface and Button Interface & Button...
LTE signal strength Indicator& status indicator Connected to Earth by conductor The LED indicators are shown in Figure 1-3. Figure 1-3 LED Indicators of EG7010A-M11 The description of LED indicators are given in Table 1-2. Table 1-2 LED Indicator Description...
Page 10
Identity Description Color Status Description Power Indicator Yellow No Power Supply Steady On Power On LTE Signal 5 LTEs, Indicate Green All OFF Signal is too weak to attach. connection state Steady On According to signal strength in and signal turn light up strength Blanking...
2. Technical Specifications Basic Specification Table 2-1 Basic Specification Item Description LTE Standard 3GPP Release 10/11 Ethernet LAN Port One RJ-45 port 10/100/1000 auto-sensing, auto-MDX, PoE LED Indicators Power/LET Signal/LAN Indicator USIM Support 1.8V/3V 2FF Restore Button Tact Button Long press over 10s to restore the factory settings Power Supply Input: Universal range 100V~240V AC Dimension...
Item Description SIM Lock Network Connection setup Create, delete, and edit APNs Set up dial-up connection automatically Set up dial-up connection manual LTE Scan Mode Full Band Cell Lock Band / Frequency Preferred ...
3. Installation Guide Support Materials Before installation, prepare the following support materials accordingly, as given in Table 3-1. Table 3-1 Support Materials for Installing Item Description Ethernet cable Outdoor Shield CAT5E Shorter than 330 feet Ground wire 16mm² yellow-green wire Install USIM Card and Ethernet Cable Screw the two screws on the waterproof cover.
Connected Ethernet cable to the power adapter, as shown Figure 3-2. Pay attention to the power adapter interface directions. Figure 3-2 Connection Diagram Power on, the LED indicator will light up. Install on Pole Tighten the screws at the bottom of the bracket,as shown in Figure 3-3. Figure 3-3 Install the Bracket Install the bracket on pole as shown as Figure 3-4.
Figure 3-4 Install on Pole Install on Wall Install bracket on wall as show as Figure 3-5. Figure 3-5 Install on Wall Grounding The EG7010A-M11 must be grounding, please contact professional person to operation.
Using grounding cable, connect the grounding screw to the ground row, as shown in Figure 3-6. Figure 3-6 Grounding Regulatory Compliance FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 18
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Warning: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
4. Configuration Guide Log in The EG7010A-M11 manages, configures, and maintains the device by web management page. The steps to log in are as follows: In the address column of browser, type in http://192.168.150.1, then press “Enter”, login in page is shown in Figure 4-1.
Figure 4-2 View Status Basic Configuration 4.3.1 LTE Setting To set the LTE Network, perform the following steps: 1. Choose LTE. 2. In the LTE Setting area, configure the LTE network. 4.3.2 Set Connection Method To set the LTE network connection method, perform the following steps: 1.
2. In the connection Method area, set the connection method 3. There are two methods to connect the LTE network, it is needed to choose a method between Auto and Manual, if you want to auto connect to the LET network you should choose the Auto, otherwise you should choose Manual.
Figure 4-5 Lock Frequency Click “SAVE & APPLY”. 4.3.5 Lock PCI To lock the PCI, perform the following steps: Choose “LTE>Scan Method”. In the LTE Scan Method area, click PCI Lock to lock the PCI. Click ADD LIST you can choose a band, frequency and PCI, then click Add to add the frequency and PCI to the list, as shown in Figure 4-6.
Appendix A FAQs The POWER indicator does not turn on. Make sure that the power cable is connected properly and the CPE is powered on. Make sure that the power adapter is compatible with the CPE. Fails to Login to the web management page. ...