Notifications; Master/Slave Status; Screen; Status Indicator - Daikin BRC1H81W Installer And User Reference Manual

Wired remote controller
Hide thumbs Also See for BRC1H81W:
Table of Contents

Advertisement

15 About the app
Result: After the download, the controller restarts to implement
changes.
15.5.3

Notifications

Get an overview of active system notifications. These can be:
▪ Errors
▪ Warnings
▪ System information
15.5.4

Master/slave status

Find out if the controller you are operating is a master or a slave
controller. It is not possible to make changes to master/slave status
from the app. For instructions on how to change a controller's
master/slave status, see
"12 Starting up the system" on
15.5.5

Screen

Make remote controller screen settings:
Setting
Home screen mode
Brightness
Contrast
INFORMATION
When making remote controller screen settings from the
app, it is possible that the remote controller does not
implement changes immediately. To make the controller
implement changes: on the controller, navigate to the
installer menu, and then back to the home screen. For
instructions on how to enter the installer menu, see
enter the installer menu" on
15.5.6

Status indicator

Make remote controller status indicator settings:
Settings
Mode
Intensity
15.5.7

Date and time

Set the remote controller date and time. In the date and time menu
you send date and time information to the remote controller from the
app. You can choose to either send the date and time information of
your mobile device ("Synchronise"), or to manually create and send
date and time information.
Installer and user reference guide
30
page 12.
Description
Switch between "Standard" or
"Detailed" home screen mode. In
"Detailed" mode, the remote
controller gives extensive system
operation through status icons,
as compared to "Standard"
mode.
Set screen brightness.
Set screen contrast.
"To
page 14.
Description
Check the active status indicator
mode. It is not possible to set the
status indicator mode from the
app; this happens through
remote controller field setting
R1-11. For more information, see
"Remote controller field
settings" on
page 19.
Set status indicator intensity.
INFORMATION
If the controller is disconnected from the power for more
than 48 hours, the date and the time need to be set again.
INFORMATION
The clock will maintain accuracy to within 30 seconds/
month.
15.5.8

About

Read out the current remote controller and remote controller
Bluetooth module software version.
15.5.9

Remove bonding information

Make the controller forget all previously bonded mobile devices.

15.5.10 Setpoint mode

Set whether the controller runs in "Indoor unit" or "Remote controller"
setpoint mode.
Setpoint mode
Indoor unit
Remote controller
INFORMATION
▪ In "Remote controller" setpoint mode, there is one
shared setpoint for Cooling and Heating operation
mode. Changing the setpoint for Cooling operation
automatically
changes
operation.
▪ When the indoor units are under control of a centralised
controller, only "Indoor unit" setpoint mode is possible.

15.5.11 Setback

Enable Setback temperature control. Setback is a function that
keeps the room temperature in a specific range when the system is
turned off. To achieve this, the system temporarily runs in Heating or
Cooling operation mode, according to the setback setpoint and
recovery differential.
Example:
10ºC
12ºC
Settings
Heating
Setback
10°C If the room temperature drops
operation
setpoint
Recovery
+2°C
differential
Description
The system uses indoor unit
setpoint logic.
The setpoint logic is the same for
Cooling and Heating operation.
the
setpoint
for
Heating
OFF
33ºC
35ºC
Result
below 10°C, the system
automatically starts heating
operation. If after 30 minutes the
temperature rises above 12°C,
the system stops heating
operation, and turns off again. If
the room temperature drops
below 10°C again, the process
gets repeated.