Operating Modes; Torque Control; Acceleration Control - SBC HPD N Series User Manual

Table of Contents

Advertisement

S.B.C. Elettronica S.p.A. - Engineering Division

3.6 Operating modes

Operating modes are selected by means of parameter Pr31, whose default value is 0. Each
operating mode commands a speed loop by means of parameter Pr6 and can limit motor torque with
parameter Pr21 (see block diagrams). Speed control uses Pr7 or Pr6 as a reference depending on
the value of b40.2. Before changing Pr31, b40.2 must be set to 0 to prevent undesired motor
movement; it is now possible to set Pr31 to the value of the chosen operating mode and load default
parameters by means of parameter b99.11. The operating mode will be enabled by setting b40.2 to
1.

3.6.1 Torque control

This operating mode (1) does not perform "classic" torque control because the speed loop
remains active to monitor limit speed; the torque reference is the main reference Pr7. To set torque
control first program the speed loop to create a stable system. Now set Pr2=1000 (10 V = 100.0 %
torque) b40.0=0 & b40.12=0; b40.2=1 to program the reserved reference, Pr31=1 to enable the
operating mode and Pr50 for maximum speed.
PARAMETERS FOR OPERATING MODE 1
Pr50
Maximum speed. Unit=rpm, default=3000, range=0..9000. This parameter makes it
possible to limit maximum absolute motor speed during torque control operation.

3.6.2 Acceleration control

Instead of performing closed loop acceleration control, this mode (2) uses main reference Pr7 for
dynamic modulation of the ramps. To program analogue acceleration control the first requirement is
a stable speed loop. When this is present set Pr2=ACC / 3.2 where ACC is acceleration in rad/s 2
required with a 10V reference signal, b40.0 = 0, b40.12 = 0, b40.2 = 1 and Pr31 = 2. Maximum
speed must be programmed in Pr50.
PARAMETERS FOR OPERATING MODE 2
Pr50
Maximum speed. Unit=rpm, default=3000, range=0..9000. This parameter makes it
possible to limit maximum absolute motor speed during operation with acceleration
reference.
Pr55
Acceleration/deceleration ramp, read-only parameter. Unit=s/krpm, range=2..30000,
resolution=1 thousandth of a second.
Pr60:61 Reserved.
Pr62:63 Reserved.
Pr66:67 Reserved.