Specifications; Before Fully Installing The Appliance - Empire Comfort Systems ONR-24-2 Installation Instructions And Owner's Manual

Outdoor ventless decorative applia
Table of Contents

Advertisement

Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment
or accessories and repair and servicing of equipment shall be per-
formed only by a qualified agency. The term "qualified agency" means
any individual, firm, corporation or company which either in person
or through a representative is engaged in and is responsible for (a)
the installation or replacement of gas piping or (b) the connection,
installation, repair or servicing of equipment, who is experienced in
such work, familiar with all precautions required and has complied
with all the requirements of the authority having jurisdiction.
commonwealth of Massachusetts: The installation must be
made by a licensed plumber or gas fitter in the Commonwealth
of Massachusetts.
The installation and the provisions for combustion and ventilation
air must conform with the National Fuel Gas Code, ANSI Z223.1/
NFPA54* Canadian Installation Code CAN/CGA B149.
*Available from the American National Standards Institute, Inc. 11
West 42nd St., New York, N.Y. 10018.
Model
Input BTU/Hr Maximum
Input BTU/Hr Minimum
Orifice
Air Shutter Opening

BEFoRE FULLY InSTALLInG ThE APPLIAnCE

If the burner is to be placed inside an outdoor firebox without
glass doors, a rain shield must be placed over the burner and
control module.
You must secure the gas log heater to the fireplace floor. If
not, the entire unit may move when you adjust the controls.
Movement of unit may cause shifting of the gas logs which
leads to improper burning.
1.
Center the gas burner in the fireplace or firebox. The grates
must clear the fireplace or firebox screen.
2.
An anchor hole is provided in the two bottom side members of
the grate frame. After centering the grate correctly, mark the
hole positions on the fireplace/firebox floor. Drill two (2) 5/32"
diameter holes approximately 1-1/2" deep for masonry screws
or 1/8" hole for sheet metal screws.
3.
Anchor the grate to the fireplace/firebox floor using the screws
provided.
Proper installation of the grate is essential to prevent any move-
ment of the gas logs and controls during operation.
Page 8
General InForMatIon (continued)

sPecIFIcatIons

onI(24,30)P
50,000
34,000
#45
Full Open
High altitude Installation
When installing this unit at an elevation above 2000 feet (in the
United States) it may be necessary to decrease the input rating by
changing the existing burner orifice to a smaller size. Generally,
input should be reduced 4 percent for each 1000 feet above sea
level. However, if the heating value of the gas has been reduced,
this general rule may not apply. Check with local gas utility for proper
orifice size identification.
For Canadian high altitude applications, this appliance is suitable for
installation at elevations between 0 feet (0m) and 4,500 (1,370m)
without change.
When installing this unit at an elevation above 4500 feet (1,370m)
(in Canada), check with local authorities.
Consult your local gas utility for assistance in determining the proper
orifice for location.
onI(24,30)n
onr(24,30)P
50,000
32,000
#29
1/8" Open
ANCHOR SCREWS
onr(24,30)n
50,000
38,000
#45
Full Open
1/8" Open
Figure 1
50,000
38,000
#29
28096-23-1016

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Onr-30-2Oni-24-2Oni-30-2