Download Print this page

Chamberlain ELITE Series Wiring Diagram page 2

Hide thumbs Also See for ELITE Series:

Advertisement

• DISCONNECT power BEFORE installing or servicing operator.
• Replace ONLY with fuse of same type and rating.
• To be compliant with UL325 and industry safety guidelines, qualified monitored
external entrapment protection devices such as photoelectric sensors or edge
sensors are required to be installed with this operator at each entrapment zone.
Use ONLY LiftMaster approved entrapment protection devices (refer to the
accessory page of manual).
• See manual regarding maintenance and required safety testing prior to servicing.
Diagnostic Codes
TO VIEW THE CODES:
Press and hold
...then press and
...then press and hold OPEN
STOP...
hold CLOSE...
until "Er" shows.
The operator will show the code sequence number followed by the code number:
A SECOND LATER....
CODE SEQUENCE NUMBER
CODE NUMBER
The first number shown is the most recent
The second number shown after the code
code (example: "01"). The display will show
sequence number is the code itself
the sequence of codes that occurred starting
(31-99, example" "31").
with "01" and going up to code "20".
TO SCROLL THROUGH THE SAVED CODES:
Press the OPEN button to cycle to the most recent code ("01"). Press the CLOSE button
to cycle to the oldest code (up to "20").
CODE COLOR KEY:
LiftMaster System
External Entrapment Protection
Installed System
Inherent Entrapment Protection
Informational
MEANING
SOLUTION
Main control board has
Disconnect all power, wait 15 seconds, then reconnect power
31
(reboot). If issue continues, replace main control board.
experienced an internal
failure.
Max-Run-Time Exceeded
Attempt to run and review for duration and obstructions.
35
Error
Max-Run-Time can be re-measured by saving one or both of
the limits again.
Product ID Error
Was the control board just replaced? If so, erase limits, enter
limit setup mode and set limits. If not, disconnect all power,
36
wait 15 seconds, then reconnect power before changing
product ID harness.
Product ID Failure
Unplug product ID harness then plug back in. Disconnect all
37
power, wait 15 seconds, then reconnect power before
replacing product ID harness.
43
Failure or missing EXIT loop
Check loop wiring throughout connection. May be a short in
the loop, or an open connection in the loop (LiftMaster Plug-
Failure or missing SHADOW
44
in Loop Detector only).
loop
Failure or missing
45
INTERRUPT loop
46
Wireless edge battery low
Replace batteries in wireless edge.
Power board fault
Relay fault detected in the power board. Replace the power
47
board.
Run-Distance Error
Limits are less than 4 feet apart or longer than what was
50
learned. Check limit positions and proper switch function.
Run-distance can be re-learned by setting the handing again.
Brownout occurred
AC/DC board supply dipped below allowable level. Review
53
power supply and wiring. If rebooting, ensure enough time
for discharge of power to force a fresh boot.
Wireless Second Operator
Check the second operator for power. If OFF, restore power
54
Communication Error
and try to run the system. If powered, deactivate the wireless
feature and then re-learn the second operator.
55
System AC Overvoltage
Call utility.
56
System AC Undervoltage
Check wiring and wire gauge to operator.
Limit Error - Stuck Switch
Check switch for proper operation. Check harness for shorts.
57
Replace if defective.
58
Limit Error - Wrong Switch
Check motor wiring.
Missing Power Board
Check harness for shorts. Check for presence of power
59
board.
Minimum number of
Review monitored entrapment protection device connections.
monitored entrapment
60
protection devices (one) not
installed.
CLOSE EYE/INTERRUPT held
Check wired input on main board; check for alignment or
61
more than 3 minutes
obstruction.
CLOSE EDGE held more than
62
3 minutes
OPEN EYE/EDGE held more
63
than 3 minutes
CLOSE EYE/INTERRUPT held
Check wired input on expansion board; check for alignment
64
more than 3 minutes
or obstruction.
CLOSE EYE/EDGE held more
65
than 3 minutes
OPEN EYE/EDGE held more
66
than 3 minutes
Wireless edge triggered more
Check wired input for wiring issue or obstruction.
67
than 3 minutes
Wireless edge loss of
Check wireless edge inputs.
68
monitoring
Wireless edge triggered
IF an obstruction occurred, no action required. If an
69
obstruction did NOT occur, check inputs and wiring.
CLOSE EYE/INTERRUPT
IF an obstruction occurred, no action required. If an
triggered, causing reversal,
obstruction did NOT occur, check alignment, inputs, and
70
preventing close, or resetting
wiring on main board.
TTC
CLOSE EDGE triggered,
71
causing reversal, preventing
close, or canceling TTC
OPEN EYE/EDGE triggered,
72
causing reversal or
preventing opening
CLOSE EYE/INTERRUPT
IF an obstruction occurred, no action required. If an
triggered, causing reversal,
obstruction did NOT occur, check alignment, inputs, and
73
preventing close, or resetting
wiring on expansion board.
TTC
CLOSE EYE/EDGE triggered,
causing reversal and
74
preventing close or canceling
TTC
OPEN EYE/EDGE triggered,
75
causing reversal or
preventing opening
Close input (EYE/EDGE)
Check inputs and communication method between operators,
80
communication fault from
either wired bus or radio. Ensure operator is powered. May
other operator
have to erase the wireless communication and reprogram the
two operators.
Open input (EYE/EDGE)
81
communication fault from
other operator
Close input (EYE/EDGE)
Check the connections between the main board and the
82
communication fault
expansion board.
(expansion board)
Open input (EYE/EDGE)
83
communication fault
(expansion board)
Force Reversal
Look for obstruction, if no obstruction, check that the
mechanical assembly is engaged and free to move. Refer to
91
manual for Limit and Force Adjustment, and Obstruction
Test.
RPM / STALL Reversal
Check for obstruction. If no obstruction, check the operator
93
cable wiring and that the operator arm is engaged and free to
move. Replace RPM assembly.
AC motor no start condition
Motor failed to start. Check for an obstructed gate or binding
95
mechanism. Check start capacitor connections and condition.
99
Normal Operation
No action required
For more information, please visit www.devancocanada.com or call toll free at 855-931-3334
CONTROL BOARD
BIPART
DELAY
4
2
6
8
OPEN
OPEN
LEFT
RIGHT
HANDING
CURRENT
MOTOR DRIVE
RPM & LIMITS ALARM EXP.
24 VAC IN
ANTENNA
SENSOR
ID RESET
BOARD
ANTENNA
CURRENT
MOTOR DRIVE
RPM & LIMITS ALARM EXP.
ID RESET
SENSOR
BOARD
2 1
10
9
8 7 6 5 4 3 2 1
4 3 2 1
2 1 4 3 2 1
Red
Blue
Orange
Yellow
Green
Gray
Purple
Black
White
RESET
BUTTON
Red
Black
PRODUCT ID
SL585U - Blue
SL595U - Black
HORSE POWER ID
1/2 HP - Yellow
1 HP - Purple
2 HP - Black
MOV ASSEMBLY
Connected across J1, J2, J3
1
2
3
4
5
6
7 8 9
3
2
1
2
1
J12
MOTOR
CURRENT
White
J14
TRANSFORMER
(BLACK)
Red
L1
12V
J1
Purple
(WHITE)
J6
J11
L2
Orange
J2
12V
(PURPLE)
J8
J7
L3
BRAKE
J3
LINE IN
J10
J13
J4
J5
3
480V
240V/208V
15
575V
MOTOR
HARNESS
POWER BOARD
THREE PHASE
EXPANSION BOARD
PLUG-IN LOOP DETECTOR
Model LOOPDETLM
SHADOW INTERUPT
EXIT
INTERRUPT LOOP
AUXILIARY
SHADOW LOOP
RELAY 1
EXIT LOOP
GATE STATE
SWITCH SETTINGS
CLOSED
1
2
3
RELAY 1
RELAY 2
OPENING
OFF
OFF OFF
Relay always off
Relay always off
OPEN
OFF OFF ON Energizes at open limit
Energizes at open limit
CLOSING
OFF
ON
OFF
Energizes when not at
Energizes when not at
Defined Mid Stop
close limit
close limit
OFF
ON
ON
Energizes when motor is on
Energizes when motor is on
Undefined Mid
Stop
Energizes 3 seconds prior
Energizes 3 seconds prior
ON
OFF
OFF
Timer more than
and during gate motion
and during gate motion
5 seconds
ON
ON
OFF
Not used
Not used
Timer less than
ON
OFF
OFF
Energizes when gate is
Energizes when gate is
5 seconds
tampered with
tampered with
* For red light ON when gate is closed, set switch 1 on AUX RELAY 1 to ON
ON
ON
ON
LEDs will blink cycle count
Not used
Jumper
3-BUTTON CONTROL STATION
N.C.
FIRE DEPARTMENT
N.C.
COM
N.O.
ACCESSORY POWER
24 Vac 500 mA Maximum
24 VAC IN
OPTIONAL ACCESSORY
WIRING
EXIT
ACCESSORY POWER
24VAC 2.2 AMPS MAX
Blue
Yellow
Yellow
Blue
Black
Red
ALARM
COM
120
208
24 VAC
240
3.15A FUSE
460
TRANSFORMER
To configure the motor for
208V, swap the orange and
SOLENOID BRAKE
red wires and plug motor
into the 208V / 240V position.
Blue
White
Yellow
15
T2
T3
THREE PHASE
Black
14
T1
Purple
13
Red
12
T8
1
White
T6
11
T7
Purple
T9
10
Blue
9
T3
Brown
T4
8
Orange
7
T5
13
Gray
6
T9
Purple
5
T6
T8
Yellow/Black
TP
T7
T5
4
Purple
T4
3
Purple
2
Yellow/Black
1
TP
T1
T2
These switches determine if the corresponding
photoelectric sensor or edge sensor will function
for the OPEN or CLOSE cycle.
POWER
EYE
PHOTOELECTRIC SENSORS
1
ONLY
EYE/
2
PHOTOELECTRIC SENSORS
EDGE
EYE/
3
EDGE
or EDGE SENSORS
COM
SBC
SINGLE BUTTON CONTROL STATION
OPN
3-BUTTON CONTROL
CLS
STP
STATION
N.C.
COM
Jumper
These switches control how the Auxiliary Relays will function.
AUXILIARY
RELAY 2
RED/GREEN
LIGHT FUNCTIONALITY
Red light
wired to AUX RELAY 1.
Green light
wired to AUX RELAY 2.
AUX RELAY 1 SWITCHES
AUX RELAY 2 SWITCHES
1
OFF
2
OFF
3
OFF
1
ON
Red light OFF*
Red light ON/FLASH
Red light OFF
Red light ON/FLASH
n/a
Red light ON
Red light OFF
Red light ON/FLASH
THREE PHASE WIRING DIAGRAM
THREE PHASE WIRING DIAGRAM
Models SL585U and SL595U
INTERRUPT LOOP
or
EXIT LOOP
PHOTOELECTRIC SENSORS for CLOSE cycle
SHADOW LOOP
Shielded Twisted Pair Cable
(Primary/Secondary link to other
gate operator) Ground the shield of
the cable to the chassis ground of
each operator.
SOLENOID LOCK
(Optional)
OR
(Not Provided)
HEATER
(Optional Accessory)
NOTE: Heater is rated for
240 VAC maximum.
Power Wiring
POWER BOARD
Three Phase
J12
MOTOR
CURRENT
J14
TRANSFORMER
(BLACK)
L1
12V
J1
(WHITE)
L2
J2
12V
(PURPLE)
L3
BRAKE
J3
LINE IN
J10
J5
J4
480V
240V/208V
575V
MOTOR
480 Vac Power Wiring
with Heater
HEATER
(Optional Accessory,
Model HTR460)
Red
Black
TRANSFORMER (Model HTR460)
Limit Switch Wiring
CONTROL BOARD
RPM & LIMITS ALA
SET
CLOSE
9
8 7 6 5 4 3 2 1
Limit Switch
2
ON
3
ON
Black
Yellow
Green light OFF
Green light OFF
Red
4
Green light ON
3
Green light OFF
Black
2
Green
1
n/a
Green light OFF
Green light ON
Green light OFF
Models SL585U and SL595U
EDGE SENSOR for CLOSE cycle
PHOTOELECTRIC SENSORS
for OPEN cycle
or
EDGE SENSOR
MAGLOCK
(Optional)
(Not Provided)
Red
Black
NOTE: The switch is
located in the electrical
box for Model SL595.
J6
J11
J8
J7
Attach
to metal
chassis
Green
JUNCTION BOX
INCOMING POWER
Red
Black
COM
120
N.C.
240
24 VAC
480
N.C.
575
FOR 480 VAC USE STEP DOWN
OPEN
Limit Switch
Blue
NC
NC
NO
NO
Black
C
C
4
3
RPM BOARD
2
1
LiftMaster.com
© 2015, LiftMaster
All Rights Reserved
01-37913-2C

Advertisement