9. Connection
9.1. Terminal plug connection
Step 1. Strip a cable jacket of approx. 7 mm from the cable end.
Step 2. Loosen the terminal screws and insert the cables.
Step 3. Tighten the terminal screws securely.
Notes
• Tug lightly on the cable to be sure that it does not pull free. If the cable pulls free, loosen the terminal
screw again and reconnect from Step 2.
• Use the screwdriver appropriate to the screws tightened into the terminal plug.
Step 4. (Removable terminal plug only)
Insert the wired terminal plug into the terminal block or the pin header.
Wiring
Take care that earth terminal "E" will be connected to earth.
Make sure to connect the frame ground terminal at the rear side to ground.
For cables, refer to
7 mm
Note
Do not solder plate on exposed inner cables when using a stran-
ded wire.
p. 10
, type of cable.
3
Tighten
4
2
Removable terminal plug (sup-
plied with the RS-410EC)
Connector
Ground
1
2
3
4
Earth
Terminal block
G 1 2 3 4 E