DESCRIPTION
TOA's VS-900 is a security communications system specially
designed for applications in such facilities as office buildings,
factories, schools, hospitals, and prisons. Installed separately
from conventional general-purpose internal communications
systems, the VS-900 can be used to access control or make
urgent calls in emergency situations.
The system is comprised of a central exchange and remote
stations, and permits calls to master stations located in the
central control room or in facility guard rooms from substations
installed in such varied locations as entrance gates, parking lots
or building entrances.
The exchange itself features modular construction that permits
easy customization to fit the desired scale and application, and
later meet changing customer needs by simply plugging in the
corresponding cards. Up to 4 master stations and 64
substations can be connected per exchange, and the system
can be expanded to up to 64 master stations and 1,024
substations through the tie-line connection of up to 16
exchanges.
A standard personal computer can also be connected to the
exchange to provide convenient adjustment of system setting
functions and automatic logging of communication operations.
A full range of exchange functions other than basic
conversation are also featured, including call forwarding, scan
monitoring, emergency conference, conversation recording by
way of external equipment, and paging by way of an external
amplifier.
There are five different types of substations, including those of
indoor-use, outdoor-use, and vandal-resistant types.
The VS-900 can also be used in combination with CCTV,
access control, emergency broadcast systems or other security
equipment to create a more effective security system and
ensure a higher level of safety and security in each facility.
VOICE SECURITY
INTERCOM SYSTEM

SYSTEM FEATURES

System Capacity
• Single Exchange
• Up to 16 Exchanges
Remote system management via RS-232C port
• PC programming and monitoring software
• Program and maintain multiple exchanges
Audio and Data Logging
• PC archive of all system activity (RS-232C port)
• Record individual Master station and telephone audio
Master Station Flexibility
• TOA master with alphanumeric display and clock
• Supports single-line telephone equipment with Caller-ID*
Outside Line Communication
• Supports two C/O trunks
• Substation to outside telephone line communication
Paging Interface
• 16 control outputs
• 1 voice output
External Audio Input
• 4 activation inputs and 1 audio input for external source
distribution
VS-900 SERIES
4 Master stations (enlargement unit: 2)
64 Substations (enlargement unit: 16)
64 Master stations
1,024 Substations
offsite from one PC (via modem)
*in compliance with FCC regulation Part 68.

Advertisement

Table of Contents
loading

Summary of Contents for Toa MS-900

  • Page 1: System Features

    DESCRIPTION TOA's VS-900 is a security communications system specially designed for applications in such facilities as office buildings, factories, schools, hospitals, and prisons. Installed separately from conventional general-purpose internal communications systems, the VS-900 can be used to access control or make urgent calls in emergency situations.
  • Page 2: System Configuration Example

    VS-900MS/AL VS-900RS/VS-910RS VS-900CO VS-900AF VS-900TI TOA MS-900 Master Station or analog (DTMF) telephone which complies with the FCC requlation Part 68 (supplied by others). RS-150, RS-160, RS-170, RS-180, RS-190 SYSTEM CONFIGURATION EXAMPLE SYSTEM SPECIFICATIONS ■ Exchange Method: PCM and space division ■...
  • Page 3: Convenient Functions

    VS-900 CALL-RELATED FUNCTION GROUP CALL A designated group of up to 16 master stations or telephones can be called from any substation, which is answered from any called master station (telephone). [System pre-programming] First, one of master stations (telephones) in a group must be programmed as a representative station, and the rest as member stations.
  • Page 4 VS-900 TELEPHONE-RELATED FUNCTIONS OUTGOING TELEPHONE CALLS Outside telephone lines can be connected to the VS-900 system, permitting the system's master stations to make or receive outside line telephone calls. [System pre-programming] A single-digit outside line access number ([0]-[9]) must first be programmed.
  • Page 5: Main Frame

    VS-900MF Note: Photo shows Main Fame with card modules installed. VS-900MS VS-900AL Main Frame 288.3 466.6 483.6 Master Station Interface Card Line 1 for master station Line 1 Voice Output Recording Control Output Line 2 for master station Line 2 Voice Output Recording Control Output...
  • Page 6: Audio Function Card

    VS-900CO VS-900AF VS-900TI Tie-Line Interface Card Outside Line Interface Card Outside Line Line 1 Line 1 Voice Output Recording Control Output Outside Line Line 2 Line 2 Voice Output Recording Control Output Audio Function Card Voice Input Control Input 1 Control Input 2 Control Input 3 Control Input 4...
  • Page 7 VS-900RS VS-910RS Substation Interface Card For External Voice Output Paging Amplifier Control Output Line 1 Line 3 for Substation Line 4 Line 2 Line 5 Line 7 Line 8 Line 6 Line 11 Line 9 Line 12 Line 10 Line 15 Line 13 Line 16 Line 14...
  • Page 8: Master Station

    MS-900 Master Station Rear panel RS-150 Substation (Indoor Type) RS-160 Substation (Indoor Vandal-Resistant Type) MS-900 can make calls to or receive calls from the substation or the master station (telephone). SPECIFICATIONS Power Source Current Consumption Talk System Talk Frequency Handset 80.5...
  • Page 9 RS-170 Substation (Outdoor Vandal-Resistant Type) rear RS-180 Substation (Outdoor Vandal-Resistant Type with Control Output) rear RS-190 Full-Duplex Substation (Indoor Type with Control Output) RS-191 Option Handset SPECIFICATIONS Rated Input Rated Impedance Output Sound Pressure Level Frequency Response Internal Speaker Call Switch Button 52.5 Weather-Resistant 57.5...
  • Page 10 Dry contact, 5V DC/0.5mA Contact resistance: 50Ω or less Communication Line 1 line for VS-900 exchange (VS-900MS card) and 1 line for MS-900 master station, 16-position 4-contact modular jack for each line In-use Indication Output Open collector output, 24V DC/ approx. 100mA, 2-pole screwless terminal Electret Microphone Input Microphone sensitivity: –75 to –65dB*, phantom power supply (power supply...
  • Page 11 2–M4 4–ø27.1 4–ø21.5 knock-out hole knock-out hole Outlet Box TOA's VS-900SC Site Connector is used to connect the VS-900 system exchanges to the fiber optical interface. SPECIFICATIONS Power Source 20V AC (supplied from the power transformer unit, under 250mA) 24V DC...
  • Page 12: Pc Interface Software

    The exchange setting contents are print out. (5) PC Port Setting Setting are made for the connection method and COM port between PC and exchange. TOA Corporation URL : http://www.toa.jp/ Specifications are subject to change without notice. Printed in Japan (0310) 833-63-161-5A U...