PBP - 03 BISTABLE RELAY
DESCRIPTION
The PBP-03 bistable relay is designed
for lighting or any other unit by means of
single pole push buttons connected in
parallel. Successive pressing of any but-
ton causes switching ON / OFF the load
connected to the output terminals alterna-
tively. The L line is a source of a control
impulse. After the impulse has arrived
t delay time will be measured and then,
the load will be OFF. It is possible to
mount the device under a push button, in
a deep junction box of 60 mm diameter.
FEATURES
یBistable lighting control,
یTime limit function,
یSoft start and switch-off (0.8 s),
یLoad ON indicator – red LED,
یDevice triggering by means of the L
wire,
یApplicable together with the single
pole push buttons, illuminated,
یTwo-conductor control system,
یEasy applicable together with any
existing electrical system,
یSupplied in series with load.
The timer should be
connected to a single-
phase system accordin-
gly to current standards.
CAUTION
The device connections
will be described in this
manual. Only qualified electricians are
allowed to assembly, connect and ad-
just the timer. It is necessary to read this
manual before the timer mounting. Do
not disassembly the timer casing or you
will lose any warranty rights and expo-
se yourself to the electric shock hazard.
Before mounting operation make sure
of disconnecting the connection wires
from the electric network.
should be carried, stored and used in
an appropriate way. Do not mount the
timer in case of any device parts lack,
damage or deformation. In case of mal-
function please notify the manufacturer.
Zakład Mechaniki i Elektroniki
J.W. Dzida, K. Łodzińska
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: marketing@zamel.pl
TECHNICAL DATA
APPERANCE
Load ON indicator
ON-time adjustment
Load power lead
Trigger conductor (IN)
Power lead (L)
Fuse socket
The timer
ZAMEL sp.j.
PBP - 03
Power terminals: L (black),
Rated voltage: 230 V
Rated voltage tolerance: -15 ÷ +10 %
Rated frequency: 50 Hz
Rated current: 8 mA
Load supply indicator: red LED
Trigger conductor: IN (red)
Load supply:
ON-time adjustment range: 10 s ÷ 16 min
ON-time setting accuracy: ±3 %
ON-time setting repeatability: ±5 %
ON-time setting: continuous (rotary potentiometer)
Permissible load: 30 ÷ 300 W
Fuse technical specification: 5 x 20 mm, ultra-fast, 2 A / 250 V
Control: triac
Connection wires quantity: 3
Connection wire section: 1 mm
Operating temperature: -20 ÷ +45
Operating position: optional
Casing fastening: for 60 mm junction box
Casing IP: IP40
Protection class: II
Overvoltage category: II
Pollution level: 2
Dimensions: 50 x 50 x 15 mm
Weight: 28 g
Standard conformity: PN-EN 60669-1, PN-EN 60669-2-1,
PN-EN 61000-4-2,3,4,5,6,11
INSTRUCTION MANUAL
brown – in series with the load
brown
2
C
o