4.5 MOTOR ROTATION DIRECTION CHECK

After the electrical wiring has been done, it is neces-
sary to check the direction of motor rotation. This
can be done by jogging the START selector switch
on the side of the control center. When looking at the
motor from the cooler end of the compressor unit,
the cooler fan should be turning clockwise. If the mo-
tor is not turning clockwise, disconnect power to the
starter and exchange any two of the three power in-
put leads, then check rotation.
A direction of rotation decal is located on the motor
shroud, next to the cooler to insure correct motor/
compressor rotation.

4.6 ELECTRICAL PREPARATION

Interior electrical wiring is performed at the factory.
Required customer wiring is minimal, but should be
done by a qualified electrician in compliance with
OSHA, National Electrical Code, and any other ap-
plicable State, Federal and local electrical codes
concerning isolation switches, fused disconnects,
etc. Sullair provides a wiring diagram for use by the
12
F igur e 2 --
1) .
installer.
A few electrical checks should be made to help as-
sure that the first start--up will be trouble--free.
1. Check incoming voltage. Be sure that compres-
sor is wired for the correct incoming voltage.
2. Check starter for correct size, proper overload
relay and heaters.
3. Check all electrical connections for tightness.
4. "Dry run" the electrical controls by disconnecting
the motor leads T1, T2, and T3 from the starter.
Energize the control circuits by turning the selec-
tor switch to the manual and automatic positions,
and check all protection devices making sure
when activated, they will de--energize the starter
control coil.
5. Reconnect the motor leads and jog the motor for
a dir ec t ion of r ot at ion c hec k as ex plained in
t ion 4.
WARNING
!
Lethal shock hazard inside. Disconnect all power
at source before opening or servicing.
5.
NOTE
Wiring diagram for standard compressors is sup-
plied on the inside cover of the Control Center.
Optional compressor wiring diagrams will vary.