Engineering Data
(Typical)
Temperature vs. Linear Output Current Fluctuation
E8F2-A01C
Rated pressure
Pressure 0
Temperature (°C)
Pressure vs. Linear Output
E8F2-A01C
Pressure (kPa)
Nomenclature
(1)
(4)
(5)
(6)
Display Panel
1. Bar Indicator (Green)
Indicates the degree of measured pressure according to the
the set pressure.
2. Numeric and Menu Display (Red)
Indicates measurement values and setting menu items.
4
(2)
(3)
(7)
(8)
Temperature vs. Operating Pressure Fluctuation
E8F2-A01C
Temperature (°C)
Linearity
E8F2-A01C
Pressure (kPa)
3. Unit Indicator (Green)
Indicates the unit used for detection. The unit indicated with
the indicator is the one currently set.
4. OUT1 Indicator (Orange)
Lit when OUT1 is turned ON.
5. OUT2 Indicator (Orange)
Lit when OUT2 is turned ON.
Operation Keys
6. Up Key
7. Down Key
•
Used to select or change the set items, set contents, and set
values in setting mode.
•
Press either key to check the ON and OFF points in
measurement mode. The values are reset by pressing both
keys simultaneously.
•
Used together with the SET Key for setting the Sensor to a
special setting mode or energy-saving mode.
8. SET Key
•
Used for entering the set contents and set values in setting
mode.
•
Used for setting the Sensor to basic setting mode or pressure
setting mode.