0
REFILL 155
(-)
EXIT
(+)
CAL HOT WATER
PRESS DISPENSE
CAL LFT PWDR VLV
PRESS DISPENSE
CAL RT PWDR VLV
PRESS DISPENSE
#### BN HPR ####
(-)
EXIT
(+)
PRE-HEAT ESP GRP
NO
EXIT
YES
SET PRE-HEAT TIME
(-)
###min (+)
SM ESP GRIND TIME
(-) #.# sec
(+)
SM PREINFUSION
(-) #.# sec
(+)
SM DWELL TIME
(-) #.# sec
(+)
SM BREW VOLUME
(-)
###
(+)
DISPENSE LOCKOUT?
NO
EXIT
YES
RINSE ALARM?
NO
EXIT
YES
RINSE ALARM TIME
(-) 12hours (+)
MENU GLOSSARY
Sets threshold for refill probe on soluble water tank. Allow adjustment for different
water conditions.
Pressing any dispense button opens the hot water valve for ten seconds. This
allows the valve to be adjusted for the proper flow rate.
Pressing any dispense button opens the left hot water valve for ten seconds.
This allows the valve to be adjusted for the proper flow rate.
Pressing any dispense button opens the right hot water valve for ten seconds.
This allows the valve to be adjusted for the proper flow rate.
This calibrates the photo sensor on the bean hopper by detecting the ambient
light with the hopper empty, then setting a threshold for signaling the hopper
is empty.
This asks if you want to enable pre heating of the espresso group if espresso
has not been brew within "X" amount of time. For espresso shots only, not for
specialty drinks.
Set amount of time in minutes, that if exceeded, will automatically go into
pre-heat routine if an espresso shot is selected to be dispense.
Set grinder run time for small espresso. Repeat of menu in
ADJUST
sub menu. Menu repeats for large espresso.
Set espresso pump run time for pre-infusion of tamped coffee. Zero seconds
for no pre-infusion Menu repeats for large espresso.
Sets dwill time in seconds between pre-infusion, and start of espresso pump
for final brewing Menu repeats for large espresso.
Sets brew volume for small espresso by flow count of flow meter menu
repeats for large espresso.
Enable locking out of beverage dispensing if either tank is not at or above ready
temperature.
Asks if you want to set an alarm if a rince cycle has not been run for "x" time since
last rinse cycle.
Set the number of hours since last rinse cycle run before signalling a rinse in
needed.