Shaking The Primary Filter; Emergency Stopping; Emptying The Container; Polyliner - Nilfisk-Advance cfm VHT37EXP Instruction Manual

Table of Contents

Advertisement

Shaking the primary filter

Figure 9-10
Depending on the vacuumed dust quantity and if the pointer
of the vacuum gauge switches from the green zone (3, Fig. 9)
to the red zone (2, Fig. 9), turn the vacuum cleaner off and
shake the main filter using the knob (1, Fig. 10).
WARNING!
Stop the vacuum cleaner before shaking the filter.
Do not shake the filter while the vacuum cleaner is on,
as this could damage the filter itself.
Wait a few seconds before restarting the vacuum cleaner, to
allow the dust to settle. Replace the filter element if the pointer
still remains in the red zone (1, Fig. 9) even after the filter has
been shaken (consult the "Primary star filter replacement"
paragraph).

Emergency stopping

Turn the manual motor starter to the "0" position.

Emptying the container

WARNING!
Before proceeding with these operations, turn off the
vacuum cleaner and remove the plug from the power
socket.
Before emptying the container it is advisable to clean the filter
(see "Shaking the primary filter" paragraph).

Polyliner

An antistatic polyliner can be used to collect dust (see Fig. 11).
In this case, the vacuum cleaner must be equipped with
optional accessories [depressor (3) and grid (2), Fig. 11].

At the end of a cleaning session

Turn off the vacuum cleaner and remove the plug from
the socket.
Coil the power supply cord and store it on the hanger at
the center of the handle (Fig. 12). Empty the container as
described in the "Emptying the container" paragraph.
Clean the vacuum cleaner as described in the
"Maintenance, cleaning and decontamination" paragraph.
Wash the container with clean water if aggressive
substances have been vacuumed.
Store the vacuum cleaner in a dry place, out of reach of
unauthorized people.
[ NOTE ]
Let the vacuum cleaner run for at least 60 seconds before
turning it off.
Wait at least 5 minutes before turning the vacuum on again.
Failure to follow these instructions could cause premature
wear of motor / starter.
02/2013
Maintenance, cleaning and
decontamination
WARNING!
The precautions described below must be taken
during all maintenance operations, including cleaning
and replacing the primary and HEPA filters.
WARNING!
The maintenance, cleaning and decontamination
operations must only be performed with the vacuum
cleaner turned off and the plug disconnected from the
power socket.
It is absolutely forbidden to perform maintenance with
the plug connected to the socket.
Danger of electric shock!
If the user is performing the maintenance operations, all
the suitable precautions should be taken. The suitable
precautions include decontamination, adequate filtered
ventilation of the exhaust air from the room in which
maintenance is performed, cleaning the maintenance
area and suitable personal protection.
WARNING!
This vacuum cleaner can be equipped with an
absolute (HEPA) filter for vacuuming dust hazardous
to one's health. The procedures for servicing and
emptying the vacuum cleaner, including removing the
dust container, must only be performed by authorized
personnel wearing protective clothing. Do not use
without the complete filter system in place.
All parts of the vacuum cleaner must be considered
contaminated when they are removed from the
hazardous zone and appropriate actions must be taken
to prevent the dispersion of dust.
When maintenance or repair procedure are carried out,
all the contaminated elements that cannot be properly
cleaned must be eliminated.
These elements must be disposed of in sealed bags,
conform to applicable regulations and in accordance with
the local laws governing the disposal of such material.
This procedure must also be followed when the filters are
eliminated (primary and absolute filters).
Compartments that are not dust-tight must be opened
with suitable tools (screwdrivers, wrenches, etc.) and
thoroughly cleaned.
9
VHT37EXP
US
C397

Hide quick links:

Advertisement

Table of Contents
loading