Dimensions (fig. 3)
Model
A (mm)
125
BDC1216
BDC1324
640
CV324
135
E-VAC1000
Controls and indicators
See fig. 4.
A - Suction motor start and stop switch.
Each switch controls a motor.
B - Mains voltage indicator light
if the indicator light is on: the electric power is supplied;
if the indicator light is off: the electric power is cut off
Inspection prior to starting
Prior to starting, check that:
-
The filter is installed;
-
All latches are tightly locked;
-
The vacuum hose "A" and the accessories have been
correctly fitted into the inlet "B" (fig. 5);
-
The bag is installed, if applicable.
-
Do not use the vacuum cleaner if the filter is faulty.
Starting up
-
Lock the castor brakes "E" (fig. 6) (if supplied) before
starting the vacuum cleaner;
-
Activate the switch "A" (fig. 4).
Vacuum cleaner operation
The primary filter clogging causes the vacuum capacity to be
reduced; therefore, it is necessary to:
-
Shake the primary filter by means of the knob "A" (fig.
7);
-
If the problem persists, replace the filter (see "Primary
filter replacement").
B (mm)
C (mm)
570
1,000
-7-
125/BDC1216/BDC1324/CV324/135/E-VAC1000
Shaking the primary filter
Depending on the vacuumed dust quantity and if the
vacuuming capability decreases considerably, shake the
primary filter by means of the knob "A" (fig. 7).
DANGER !
Stop the vacuum cleaner before shaking the filter.
Do not shake the filter while the vacuum cleaner is on,
as this could damage the filter itself.
Wait before restarting the vacuum cleaner, to allow the dust
to settle.
Replace the filter element if the vacuuming capability is
still low even after the filter has been shaken (consult the
"Primary filter replacement" paragraph).
Emergency stopping
Activate the switch "A" (fig. 4).
Emptying the container
DANGER !
Before proceeding with these operations, turn off the
vacuum cleaner and remove the plug from the power
socket.
-
Before emptying the container it is advisable to clean
the filter (see "Shaking the primary filter" paragraph).
-
Release the dust container "A" (fig. 8), then remove and
empty it.
-
Make sure that the gasket is in perfect condition and
correctly positioned.
-
Place the container back in position and secure it again.
Paper bag
A paper bag "A" (fig. 14) can be used to collect dust.
At the end of a cleaning session
1 -
Turn off the vacuum cleaner and remove the plug from
the socket.
2 - Wind the connection cable (fig. 9).
3 - Empty the container as described in the "Emptying the
container" paragraph. Clean the vacuum cleaner as
described in the "Maintenance and cleaning" paragraph.
4 - Wash the container with clean water if aggressive
substances have been vacuumed.
5 - Store the vacuum cleaner in a dry place, out of reach of
unauthorized people.
GB