Connecting The 1-Inch Dla - Waterous AQUIS ULTRAFLOW Installation And Operation Manual

Table of Contents

Advertisement

Safety
Introduction

Connecting the 1-Inch DLA

2
M
F
M
F
1
3
M
F
Product Overview
4
|
54
62
Installation
Operation
Use the illustration and instructions to connect the
1-inch DLA to the control box, and the paddlewheel
flowmeter to the node controller.
1 Connect the split CANbus cable to the CANbus
connector on the node controller.
2 Connect the male end on the split CANbus
cable to an upstream node controller, or to the
control box—the discharge CANbus connection.
Note: Use an additional CANbus cable if
necessary.
3 Connect the female end on the CANbus splitter
cable to the next, downstream node controller,
or to a terminating resister if this is the last
downstream node controller in the system.
Note: Use an additional CANbus cable if
necessary.
4 Use a sensor cable to connect the paddlewheel
flowmeter to the node controller.
Note: Use an additional sensor cable if
necessary.
I-2251 L-1222-1