Waterous AQUIS ULTRAFLOW Installation And Operation Manual page 39

Table of Contents

Advertisement

Safety
Introduction
Electrical and Cable Connections—Overview
Feature
Feature
1
Apparatus power
2
Frame ground
3
Negative terminal wire
4
Terminal block
5
HMI terminating resister
6
HMI power cable
7
HMI cable.
8
HMI CANbus cable
9
Split CANbus cable
10 CANbus extension cable
11 Remote I/O cable
12 Hydraulic pump cable
13 Concentrate pump cable
14 Concentrate supply sensor cable
15 Water pressure cable
16 Manual override relay cable
17 Manual override switch cable
18 Relay power cable
19 PLC cable
20 Breaker box
21 Power disconnect relay—200A
22 DLA cable
23 Priming valve cable
24 DLA terminating resistor
25 Flowmeter cable
26 Control valve cable extension
Product Overview
Description
Description
This supplies power to the system—installer supplied.
This connects the negative (–) terminal to the apparatus frame—installer supplied.
This connects to, or through terminal blocks, to the negative (–) terminal on the apparatus battery—installer
supplied.
This allows you to distribute multiple power circuits from one supply—installer supplied.
This terminates the CANbus connection on the HMI cable.
This supplies power to the HMI and requires a 5 amp circuit breaker—installer supplied.
This connects the HMI to power and connects to the CANbus.
This connects the HMI to the PLC.
This connects the node controllers to one another.
This provides an extension to the split CANbus
This connects to any remote I/O components.
These harnesses connect to sensors that monitor the hydraulic fluid level and temperature as well as control the
hydraulic pump.
These harnesses connect to sensors that monitor the concentrate pump speed and discharge pressure as well as
monitoring the pump intake select switch. The intake select switch is installer supplied.
These harnesses connect the concentrate supply sensors. The sensing method is determined by installer and level
sensor or high/low switches are installer supplied.
This connects to the water pressure sensor on the water pump.
This connects to the power relay that disables power to the DLAs.
This connects the manual override switch to the control box.
This supplies power to the power disconnect relay and requires a 5 amp circuit breaker—installer supplied.
This supplies power to the PLC and requires a 5 amp circuit breaker—installer supplied.
This organizes the circuit breakers and distributes apparatus power—installer supplied.
This is a 200 amp power relay that enables and disables power to the DLAs.
This supplies power to the DLA and requires a 10 amp circuit breaker per DLA—installer supplied.
This connects the priming valve to power and CANbus control.
This terminates the CANbus connection on the last node controller in the CANbus chain.
This connects the flowmeter, magnetic or paddlewheel, to the node controller.
This connects the DLA control valve to the node controller.