1.0

Introduction

This guide outlines the required steps to upgrade the firmware of the Any-Grid™ PSW-H hybrid inverter model
mentioned in the filename of the upgrade zip package.
Before proceeding, check the currently installed "Main Unit" (U1) firmware by scrolling though the Any-Grid LCD's
screen views by pressing
In this example the Version 30.00 is shown.
Keep scrolling to find the "Display Unit" (U2) firmware version until this view is shown:
In this example the Version 06.00 is shown.
WARNING: Be sure the Any-Grid unit is only connected to a battery. PV and all AC connections must be
disconnected for your own safety. Also, any parallel communication and current sharing cables must be
disconnected.
If no battery or DC source is available, the Any-Grid may be powered from an AC source via the AC input. In
this case the firmware update may only be done by a trained professional. AC load output, PV and battery
terminals and any parallel and current sharing cables must be disconnected when choosing to proceed with
an AC source.
Make sure the upgrade procedure is undertaken with the bottom cover closed, so that no terminals are
accidentally touched during the procedure. Failure to do so could cause serious injury due to electrocution.
2.0

Requirements

To upgrade the Any-Grid, the following is required:
Any-Grid PSW-H unit – model as mentioned in the filename of the upgrade zip package
Firmware upgrade file(s) in zip package provided by your Phocos dealer
RS-232 cable (RJ-45 to SUB-D connectors) provided with every Any-Grid unit
Using any other cable than the one provided may damage the Any-Grid and/or your PC and void your
warranty.
Windows PC (tested on Windows 7 and Windows 10)
Native RS-232 port on the Windows PC. If no such port is available, a standard USB to RS-232 adaptor may be
used to create a virtual COM port. This guide assumes that if a USB adaptor is used, the drivers are correctly
installed. The COM port number assigned must be between 1 and 9.
This guide, which is valid for both a "Main Unit" or "Display Unit" upgrade. Follow the section(s) which is/are
relevant for the upgrade(s) you require. If both are to be upgraded, proceed with the "Main Unit" and if
successful, continue with the "Display Unit" upgrade.