Sat-audio transmodulator, 2 x dvb-s (qpsk) - 6 x fm (14 pages)
Summary of Contents for Blankom HDC 6012
Page 1
128 IPTV inputs (UDP, RTP, MPTS & SPTS) 4 groups multiplexing +4 groups scrambling 4 adjacent QAM channels (DVB-C / ITU Annex-B) The BLANKOM HDC-6012 is Excellent RF output performance index, MER ≥ 43 dB a high performance and ...
HDC 6012 User Manual & Datasheet Table of Content: Inhalt Table of Content: ............................2 Application Example: ............................ 4 Technical specifications: ..........................5 Entering WEB-Interface (Web-IF) by NMS-Port: ..................6 Setting up NTP-Server for i.e. Europe: ......................6 Setting up Tuner Inputs: ..........................7 Setting up incoming IP-Streams: ........................
Page 3
HDC 6012 User Manual & Datasheet BLANKOM-HDC-6012_Manual_EN-RR-06-2021_V1.5.docx...
HDC 6012 User Manual & Datasheet Entering WEB-Interface (Web-IF) by NMS-Port: The default IP-Address is 192.168.0.136. We recommend to use the latest Firefox Browser. User/password is per default: admin / admin and you end up in the Status window: Setting up NTP-Server for i.e. Europe:...
HDC 6012 User Manual & Datasheet Because the webserver access is almost necessary for the first time setup of this transmodulator. So first chose your region , than try to get some NTP-Server addresses from the internet like: Or use: Setting up Tuner Inputs: Of course, L-Band as well as Ku &...
Page 8
HDC 6012 User Manual & Datasheet Enter the values: 10741.25 as frequency, Horizontal = 18V ON, Symbolrate =22000, SAT pos. 1 (depending on your Multiswitch), LOW Band = 22KHz off, FEC will be detected: wait some moments and e' Voila:...
Page 9
HDC 6012 User Manual & Datasheet We recommend not to use the Loop through RF Inputs with the Rear-Tuners because of more signal attenuation and the cascaded tuner input must use the same SAT-position/polarisation/band as the first one by avoiding different polarisations (H/V) and low-High-Band – must be equal.
HDC 6012 User Manual & Datasheet be sure to enter as "." instead of a komma "," The limit from low to high band is: 11700MHz, so all frequencies above need to set the high band LNB IF of 10600 MHz and the 22KHz need to be switched on.
Page 11
HDC 6012 User Manual & Datasheet Here you can see all tuner inputs even with bitrates received but no content yet. First we have already added a SPTS from 239.42.22.1 Multicast address as UDP with port number 1234. So we add an MPTS coming as Multicast from: 239.100.1.100:1234:...
Page 12
HDC 6012 User Manual & Datasheet Now we need to parse each tuner and IP stream content to the machine: or parse step by step each marked Tuner1...12 and IP streams. Parse – select all SPTS already assigns the SPTS to the output.
Page 13
HDC 6012 User Manual & Datasheet By selecting the input and click, you get more information and can select services to the output on the right side: CA-Filter needs only to be checked, if the Service was scrambled, somehow decrypted (i.e. coming as MPTS or SPTS and containing still CA-Flags and maybe EMM/ECM PIDs which are filktered out by this CA Filter –...
HDC 6012 User Manual & Datasheet Network Information Table: Anyway the NIT should be re-generated for the DVB-C Tuners in your network by: Select the output frequencies and values for the QAM channels: high bandwidth can be reached by i.e.: 256 QAM, Srate 6950, low FEC: you can add all other channels from your network here to generate a common NIT for all of them.
HDC 6012 User Manual & Datasheet Adjusting RF-QAM output: Changings to the Modulator part is now the right time: So we adjust the own DVB-C RF-channels here: Because the channels are adjacent 4x 8 MHz and we don't use the american Annex-B standard (ITU), we get the overall settings as: The SPTS is already inserted into Ch 1.
Page 16
HDC 6012 User Manual & Datasheet PID remapping is recommended to avoid collisions. To avoid an Overflow, you should always consider an overhead of 10...15% because the peaks would disturb all services in the bouquet – which isn't that nice for the receivers in your network.
Page 17
HDC 6012 User Manual & Datasheet So better to get rid of one of them: Thats not enough: so we delete a 2nd one: Thats much better: To get the full information, just click on a service: And you can manipulate every single PID inside that service as well as the name...:...
HDC 6012 User Manual & Datasheet BISS decryption You can descramble a selected service by a BISS key which you need to configure before in the BISS section: Than select this key: BLANKOM-HDC-6012_Manual_EN-RR-06-2021_V1.5.docx...
Page 19
HDC 6012 User Manual & Datasheet It will be shown now and selectable in the Programm Information BLANKOM-HDC-6012_Manual_EN-RR-06-2021_V1.5.docx...
HDC 6012 User Manual & Datasheet Conditional Access encryption: The already configured output multiplexes can be simul-encrypted by up to 4 different CA Systems. The configuration is nearly self explaining. Multiplexer Back to the Multiplexer. We configure TS 2-4 now: TS2: The IP inputs must be configured again: BLANKOM-HDC-6012_Manual_EN-RR-06-2021_V1.5.docx...
Page 21
HDC 6012 User Manual & Datasheet with the PID-Bypass you can pass individual PIDs from the Inputs to the outputs: BLANKOM-HDC-6012_Manual_EN-RR-06-2021_V1.5.docx...
Page 22
HDC 6012 User Manual & Datasheet After adding another IP stream, parse the content and assign it to the Output with CA Filter and PID remapping: The CA – components are filtered out and the PIDs are remapped. After finally all QAM Outputs are configured – maybe write a new NIT - we can pass these multiplexes to MPTS IP Output to transmit them by an ethernet network to another modulator or station: BLANKOM-HDC-6012_Manual_EN-RR-06-2021_V1.5.docx...
Page 23
HDC 6012 User Manual & Datasheet Each of them can be configured as scrambled (if CAS is setup) or even as unscrambled, you can set it as VBR (null paket filter enables) as RTP or UDP: BLANKOM-HDC-6012_Manual_EN-RR-06-2021_V1.5.docx...
HDC 6012 User Manual & Datasheet Network Settings: Scrambler and NMS –are on the same Ethernet RJ45 port with 100BaseT while the DATA port has GbE. NMS and scrambler-communication port IP addresses can be configured individually. Configuration Backup Restore: BLANKOM-HDC-6012_Manual_EN-RR-06-2021_V1.5.docx...
HDC 6012 User Manual & Datasheet Save will internally save your config, but we recommend to backup the file to your computer: Restoring works vice versa... Firmware upgrade: is nearly selfexplaining... BLANKOM-HDC-6012_Manual_EN-RR-06-2021_V1.5.docx...
Page 26
HDC 6012 User Manual & Datasheet BLANKOM-HDC-6012_Manual_EN-RR-06-2021_V1.5.docx...
HDC 6012 User Manual & Datasheet Logs: should be sent to us in case of support issues. Please note: Remultiplexing would destroy EPG data from the original source. This cost effective Receiver / multiplexer / scrambler / modulator does not support EIT remultiplexing.
Installation Notes All types of the IRENIS-BLANKOM family are 19“devices with 1 RU height designed for installation in 19” racks. In addition to the front panel screws an internal module support is required at the rack. Depending on the Frontend used and the operating adjustments, the RF-input port carries DC Voltage (13V /18V, max.
HDC 6012 User Manual & Datasheet Note: IPv4 global scope sessions use multicast addresses in the range 224.2.128.0 - 224.2.255.255 with SAP Announcements being sent to 224.2.127.254 Port 9875 (note that 224.2.127.255 is used by the obsolete SAPv0 and MUST NOT be used).
Page 33
HDC 6012 User Manual & Datasheet Appendix A Product Disposal Warning! Ultimate disposal of this product should be handled according to all national laws and regulations. 製品の廃棄 この製品を廃棄処分する場合、国の関係する全ての法律・条例に従い処理する必要がありま す。 警告 本产品的废弃处理应根据所有国家的法律和规章进行。 警告 本產品的廢棄處理應根據所有國家的法律和規章進行。 Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen.
HDC 6012 User Manual & Datasheet Safety instructions Read the safety instructions carefully before assembling or commissioning the device and ensure that you comply with them 1. Installation Danger: The device may only be installed and started up by competent people (see EN 60065).
Page 35
HDC 6012 User Manual & Datasheet 3. Maintenance Danger: Maintenance tasks must always be carried out by competent people (see EN 60065). Danger: Do not carry out servicing work during thunderstorms. There is a risk of electric shock (danger of death).
HDC 6012 User Manual & Datasheet Sicherheitshinweise Sicherheitshinweise bitte vor Montage bzw. Inbetriebnahme des Gerätes sorgfältig lesen und befolgen. Installation Gefahr: Das Gerät darf ausschließlich von sachverständigen Personen (siehe EN 60065), installiert und in Betrieb genommen werden. Gefahr: Das Gerät und/oder die Verteilperipherie muß vor Inbetriebnahme gemäß EN 60728-11 vorschriftsmäßig geerdet sein (Potentialausgleich) und bleiben, auch wenn das Gerät ausgebaut wird.
HDC 6012 User Manual & Datasheet Warnung: Befolgen Sie alle Instruktionen in der gerätespezifischen Bedienungsanleitung. Wartung Gefahr: Wartungsarbeiten sind stets von sachverständigen Personen (siehe EN 60065) vorzunehmen. Gefahr: Keine Servicearbeiten bei Gewitter. Es droht Gefahr eines elektrischen Schlags (Lebensgefahr). Warnung: (nur für Geräte mit Batterie): Explosionsgefahr bei unsachgemäßem Auswechseln der Batterie.
HDC 6012 User Manual & Datasheet Installation guide for F-connectors: / Installationshinweis für den F-Anschluß: Die LNB-Anschlüsse sind meist entsprechend gekennzeichnet The LNC –connectors at Multiswitches are almost marked as: HH= Horizontal High-Band HL = Horizontal Low-Band = LH VL = Vertical Low-Band = LV Elektronische Geräte gehören nicht in den Hausmüll, sondern müssen - gemäß...
Need help?
Do you have a question about the HDC 6012 and is the answer not in the manual?
Questions and answers