Connection And Securing Of The Inner Cable - Shimano GRX RD-RX810 Dealer's Manual

Table of Contents

Advertisement

Adjustment

Connection and securing of the inner cable

6.
Install the cap with long tongue to the end.
The end of the outer casing which has the sealed outer cap (aluminum type) should be on
the shifting unit side.
Route the inner cable through the outer casing.
Connection and securing of the inner cable
1.
Set the shifting lever in its initial position.
Operate the release lever 10 times or more.
2.
Secure the inner cable to the rear derailleur.
There is no cover with tongue for RD-RX400.
NOTICE
• When replacing the inner cable for RD-RX810/RD-RX812, it is recommended to
replace the cover with tongue.
• Cables with a polymer coating may develop a fuzzy appearance or texture
through natural wear when used. However, if the cables are installed with care
according to the procedures outlined in this manual, this is strictly cosmetic and
performance will not be affected where the inner cables are housed by outer
casing.
Sealed outer cap
(aluminum type)
Inner cable
OT-RS900
Cap with long tongue
Cover with
tongue
16