Air Filter; Caring For The Air Filter - Dukane ImagePro 9135 User Manual

Portable lcd projector
Hide thumbs Also See for ImagePro 9135:
Table of Contents

Advertisement

Air Filter

Air Filter
WARNING • Please carefully read the "User's Manual - Safety Guide.
• Before caring, make sure the power switch is off and the power cable is not
plugged in, then wait at least 45 minutes for the lamp to cool sufficiently.
• Use only the air filter of the specified type NJ08081.
• Do not use the projector with the air filter and filter cover removed. The use without
the air filter could result in damage.
CAUTION • If the air filter becomes clogged by dust or the like, internal
temperature rises and could cause malfunction. The power is automatically turned
off in order to prevent the projector from overheating internally.

Caring For The Air Filter

Cleaning the air filter every 100 hours using the FILTER MESSAGE function
recommended. If the indicators or a message prompts you to clean the air filter, clean the
air filter as soon as possible. Please check and clean the air filter periodically, even if
there is no message. If the soiling will not come off the air filter, or it becomes damaged,
then it needs to be replaced. Please replace the air filter as soon as possible.
When you replace the lamp, please replace also the air filter.
memo
Turn off the projector, and unplug the power cord. Allow the lamp bulb to cool for at
1
least 45 minutes.
After making sure that the projector has cooled adequately, remove the filter cover
2
and air filter.
Apply a vacuum cleaner to the top of the filter cover and
3
the air filter to clean.
If the soiling will not come off the air filter, or it becomes
damaged, it needs to be replaced.
If the air filter needs to be replaced, contact your dealer
to prepare a new air filter. Tell the dealer your air filter
type.
Insert the cleaned air filter or a new air filter, and replace
4
the filter cover.
Turn on the projector power, and reset the filter timer.
5
(1) While the projector running, press the MENU button to
open the menu.
(2) Choose the "OPTION" on the menu using the
button, then press the
(3) Choose the "FILTER TIME" using the
press the
(4) Choose the "RESET" using the
Incorrectly resetting of the filter timer (resetting
memo
without replacement, or neglect of resetting after replacement) will result in
incorrect message functions.
button or ENTER button.
button or RESET button.
/
button, then
/
button.
is
34
Hold the release
buttons of the filter
cover while pulling
down it.
Hold the release button
of the air filter while
pulling out it.