Commissioning; Description Of The System Housing - Bosch rexroth NYCe 4000 Manual

Linear motion control system
Hide thumbs Also See for rexroth NYCe 4000:
Table of Contents

Advertisement

18/27

Description of the System Housing

Then disconnect the "24V System" power supply connector. Finally, disconnect
all remaining connectors and protective earth connections.
Remove the screws that mount the system housing on the metal surface in the
machine.

11 Commissioning

Check that the system housing is mechanically solid mounted in the machine.
Verify that the protective earth connection is correctly connected.
Check that proper cabling is used.
Check that the shielding of shielded cables is correctly connected.
Check that cables are not damaged.
Install the MCU module in the left-most slot called "MCU" and the SERCOS III
Master module in the slot at the right side called "S III" in the module holder of
the system housing. See the Instructions of the MCU module and SERCOS III
Master module.
12 Description of the System Housing
The system housing has no indicators.
Bosch Rexroth AG R911383228_Edition 04
NYCe 4000 Linear motion control sys-
tem

Advertisement