4 Intended Use

The system housing is for indoor use only, and may only be used with parts
indicated in this document. Not explicitly mentioned parts may not be installed
or connected. This also applies to cables. Usage is only allowed in explicitly
indicated combinations of parts.
Do not install and use this system housing before you have read all relevant
documents. You must read the safety instructions and all other directions for
use before you start any work or activity with this system housing.
The system housing has no certified functional safety on board. This means that
all precautions for a safe operation must be ensured by external components.

5 Accessories, Spare Parts and Wear Parts

The following accessories are available for this system housing.
Type code
NYA04.1-FAN-1DRV-NY4922/00
Tab. 5-1: Accessories for the NY4079 system housing
The system housing does not contain any replaceable or wear parts. In case of
failure, the entire system housing must be replaced.

6 Ambient Conditions

Maximum environment
temperature
Relative Humidity
Mechanical strength
Pollution degree
Overvoltage category
Maximum altitude
Tab. 6-1: Ambient conditions
Degrees of protection provided by enclosures: IP20.
Free air flow in vertical direction is required above and below the system
housing for a distance of minimal 10 cm for forced cooled systems and 20 cm
for convection cooled systems.
If convection cooling is used (instead of forced cooling) the system housing
must be installed vertical to ensure sufficient free air flow through the
Operating
+5 °C .. +55 °C
10 % .. 90 % (non-condensing)
Vibration: IEC 60068-2-6:2007
Vibration,
IEC 60068-2-64:2008
2
II
4000 m
Material number
Description
R911328062
Fan unit – 1 drive slot
Storage and transport
–40 °C .. +85 °C
5 % .. 95 % (non-condensing)
Shock: IEC 60068-2-27:2008
broad-band:
2
-
R911383228_Edition 04 Bosch Rexroth AG
7/27
Ambient Conditions