NYCe 4000 Multi-axis motion control
system
10.8 Mechanical removal of the system housing
DANGER
Do not touch the pins of this connector.
Do not touch the rear side of the backplane.
Make sure that all power supplies are switched off and capacitors in the system
are fully discharged before you remove the system housing.
First, disconnect all drive power supply connectors ("DP" and "DP NY4130").
Then disconnect the "24V System" power supply connector. Finally, disconnect
all remaining connectors and protective earth connections.
Remove the screws that mount the system housing on the metal surface in the
machine.
11 Commissioning
Check that the system housing is mechanically solid mounted in the machine.
●
Verify that the protective earth connection is correctly connected.
●
Check that proper cabling is used.
●
Check that appropriate fuses of correct rating are installed for drive power
●
and digital I/O power supplies.
Check that power supply cables and motor cables are installed with proper
●
strain reliefs.
Check that the shielding of shielded cables is correctly connected.
●
Check that cables are not damaged.
●
12 Description of the System Housing
The system housings have no indicators.
Description of the System Housing
Voltage on the pins of the "DPx" drive power
connector can be higher than 60V DC. When the
connector is unplugged a high voltage can
remain present on the pins for 5 minutes after
disconnection.
If
accompanying capacitor installed and the drive
module is not installed in that drive slot, you
must wait 30 minutes.
R911337318_Edition 09 Bosch Rexroth AG
a
drive
slot
has
37/45
an