Table of contents
1 Screen transitions .............................. 2
2 Monitor mode ..................................... 6
2.1
Overview of monitor mode ......................6
2.2
Monitored items ......................................6
3 Parameter mode ................................ 9
3.1
Types of parameters ...............................9
3.2
Setting example ....................................10
3.3
Speed filter parameters...................... 11
I/O parameters................................... 12
Normal mode parameters .................. 13
Alarm warning parameters ................ 14
parameters ......................................... 14
Data setter parameters ....................... 15
OPX-2A
EAS
Series
3.4
Electronic gear parameters ................ 15
3.5
Initializing parameters .......................... 16
4 Test mode ........................................ 17
4.1
Overview of test mode.......................... 17
4.2
I/O test.................................................. 17
4.3
JOG operation ...................................... 18
4.4
4.5
Electrical home reset............................ 18
5 Copy mode....................................... 19
5.1
Overview of copy mode........................ 19
5.2
Downloading to the driver..................... 20
Uploading to the OPX-2A..................... 20
5.3
5.4
Verifying parameters ............................ 21
5.5
Initializing driver parameters................. 21
HL-14054

Advertisement

Table of Contents
loading

Summary of Contents for Oriental motor DG II Series

  • Page 1: Table Of Contents

    DGⅡ / Series Series OPERATING MANUAL Thank you for purchasing an Oriental Motor product. This operating manual describes product handling procedures and safety precautions. • Please read it thoroughly to ensure safe operation. • Always keep the manual where it is readily available.
  • Page 2: Screen Transitions

    1 Screen transitions Screen transitions Top screen Monitor mode Parameter mode Speed Application parameters Position Operating current Speed filter Data setter APP-8 Present alarm Operating current 0 Speed filter 0 I/O input mode Alarm record 1 (latest) Alarm signal output Operating current 15 Speed filter 15 Alarm record 10 (oldest)
  • Page 3 1 Screen transitions Do not perform push-motion operation with the DGⅡ Series. Doing so may result in damage to • Note the motor or gear part. • The following limitations are present while the edit lock function is enabled. ・Parameter mode, copy mode: These are displayed on the screen but cannot be operated. ・Clearing of the alarm and warning records, reset of the electrical home: These are not displayed on the screen.
  • Page 4 1 Screen transitions Parameter mode System parameters Application parameters Manual operation Data setter Electronic gear Operation setting Return to Operating electrical current home operation APP-0 APP-6 Operating speed of Displayed speed on Electronic gear A1 Pulse input mode OPX-2 JOG operation Electronic gear A2 Smooth drive Acceleration and...
  • Page 5 1 Screen transitions Test mode Copy mode Monitor mode I/O test Download Data bank selection 0 Execute Input test (blinking display) Output test 1 Data bank selection 3 Execute (blinking display) Output test 1 Upload Output test 2 Data bank selection 0 Execute Output test 2 (blinking display)
  • Page 6: Monitor Mode

    2 Monitor mode Monitor mode 2.1 Overview of monitor mode • Monitoring the operating status The speed and position of the motor can be monitored in real time. • Checking alarms/warnings, clearing alarm/warning records, and resetting alarms • If an alarm or warning generates, since a corresponding alarm code or warning code will be displayed, the details of the alarm/warning can be checked.
  • Page 7 2 Monitor mode Alarm code list Number of Number of Resetting times the Resetting times the Code Alarm name on the driver’s Code Alarm name on the driver’s OPX-2A OPX-2A ALARM LED ALARM LED blinks blinks Overflow rotation Possible Overload Possible during current on Overflow rotation...
  • Page 8 2 Monitor mode I/O monitor You can check the ON/OFF status of each I/O signal of the driver. Each digit on the 7-segment LED display corresponds to a signal. If the signal is ON, the corresponding digit is lit. If the signal is OFF, the digit is unlit. •...
  • Page 9: Parameter Mode

    3 Parameter mode Parameter mode You can set parameters relating to operation and control. These parameters are saved in the Actuator driver. Before setting parameters, read the carefully to understand the basic operations, USER MANUAL functions and other details of the driver. •...
  • Page 10: Setting Example

    3 Parameter mode 3.2 Setting example Pressing the key in the parameter item screen enables parameter setting. How a parameter is set is explained below. Example: Set operating current setting 0 to “50” Top screen of the parameter mode Press the key to move to the parameter mode.
  • Page 11: Description Of Application Parameters

    3 Parameter mode 3.3 Description of application parameters Operating current parameters Display on the Initial Parameter name Description Setting range OPX-2A value APP-0-00 Operating current APP-0-01 12.5 Operating current APP-0-02 18.8 Operating current APP-0-03 25.0 Operating current APP-0-04 31.3 Operating current APP-0-05 37.5 Operating current...
  • Page 12: I/O Parameters

    3 Parameter mode I/O parameters Display on the Initial Parameter name Description Setting range OPX-2A value 0:Positioning Selects the input signal mode. operation I/O input mode APP-2-00 For push-motion operation, refer to the 1:Push-motion following explanation on this page. operation 0: Disable Changes the setting to enable/ disable Alarm code...
  • Page 13: Normal Mode Parameters

    3 Parameter mode Normal mode parameters Display on the Initial Parameter name Description Setting range OPX-2A value Sets the standstill current as a APP-3-00 0.0 to 50.0[%] 50.0 Standstill current percentage of the operating current. Sets the speed error gain. When this value is increased, actuator vibration APP-3-01 0 to 500...
  • Page 14: Alarm Warning Parameters

    3 Parameter mode Alarm warning parameters Display on the Initial Parameter name Description Setting range OPX-2A value Changes the setting to enable/disable 0: Disable Abnormal operation APP-5-00 the abnormal operation data warning data warning 1: Enable output. Sets the condition under which an Overflow rotation overflow rotation alarm during current 0.01 to 300.00...
  • Page 15: Manual Operation Parameters

    3 Parameter mode Manual operation parameters Display on the Initial Parameter name Description Setting range OPX-2A value Sets the operating speed of JOG 1 to 4000 Operating speed of APP-7-00 [r/min] operation. JOG operation Acceleration and Sets the acceleration and deceleration 0.01 to 1000.00 APP-7-01 100.00...
  • Page 16: Operation Setting Parameters

    3 Parameter mode Operation setting parameters Display on the Initial Parameter name Description Setting range OPX-2A value 0: Setting by the pulse input mode selector switch 1: 2-pulse input mode, negative logic 2: 2-pulse input mode, positive logic 3: 1-pulse input mode, negative logic Selects the pulse input SYS-1-00...
  • Page 17: Test Mode

    4 Test mode Test mode 4.1 Overview of test mode • I/O test You can check the ON/OFF status of each input signal of the driver. You can also switch the ON/OFF status of each output signal on the OPX-2A. There is also an I/O test function with which you can check the connection status of the driver.
  • Page 18: Jog Operation

    4 Test mode 4.3 JOG operation You can operate the motor using the keys on the OPX-2A. When pressing the key once, the motor rotates by one step in the positive direction. If the key is kept pressing, the motor rotates in the positive direction continuously. When pressing the key once, the motor rotates by one step in the negative direction.
  • Page 19: Copy Mode

    5 Copy mode Copy mode The OPX-2A has four data banks, and parameters can be saved in each of these data banks. Since an EEPROM is used for the data memory, stored parameters will be retained even after the power is turned off.
  • Page 20: Downloading To The Driver

    5 Copy mode 5.2 Downloading to the driver In this operation, parameters of the specified data Download OPX-2A bank number are downloaded to the driver. data to the driver. If a download error occurs, a code indicating the nature of the error will blink on the display. Download will not be performed and the display will return to the top screen of download.
  • Page 21: Verifying Parameters

    5 Copy mode 5.4 Verifying parameters In this operation, parameters in the specified data bank number are verified against the corresponding parameters saved in the driver. If the verification finds that the two sets of parameters match, “Good” will be shown. If the two do not match, “Error”...
  • Page 22 -22-...
  • Page 23 -23-...
  • Page 24 If a new copy is required to replace an original manual that has been damaged or lost, please contact your nearest Oriental Motor branch or sales office. • Oriental Motor shall not be liable whatsoever for any problems relating to industrial property rights arising from use of any information, circuit, equipment or device provided or referenced in this manual.