Dimensional Sketches - Grundfos DDI 222 Installation And Operating Instructions Manual

Dosing pump
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
4.4.3 Dosing control (Flow Monitor)
The pressure sensor (Flow Monitor pump option) is used as a
dosing controller and to monitor the pressure for the whole power
ranges.
The Flow Monitor for dosing control consists of a pressure sensor
integrated in the dosing head.
The pressure sensor is available as Flow Monitor pump option.
The pressure sensor is fitted to the pump on delivery. Upgrades
are not possible.
Pressure control is primarily used to protect the
pump. This function is not a substitute for the
Note
overflow valve.

4.5 Dimensional sketches

MLS
D1
C4
C1
DS
10
Fig. 4
DDI 222
Dimensions for DDI 222
A3
[mm]
DDI 60-10
283
DDI 150-4
315
DDI 60-10 / HV
295
DDI 150-4 / HV
315
12
A4
A3
Ø7
16.5
(159)
172.5
207
A5
A4
A5
B3
[mm]
[mm]
[mm]
338
306
137
372
350
137
350
328
137
372
350
137
4.4.4 Flow compensation
The flow compensation is a function to keep the dosing flow
constant with changing system pressure. Pressure changes are
detected by the pressure sensor and the motor speed is adjusted
accordingly.
To use this function, pressure control or dosing control (Flow
Monitor) has to be activated in the electronics.
When dosing media with a viscosity similar to water,
the pump needs not to be calibrated, as the pump
already responds to the possible change of the
system pressure.
Note
When dosing media with a viscosity different from
water or after a software update, the pump has to be
calibrated.
61.5
105
123
B3
B4
MBS: Diaphragm leakage sensor (optional)
DS: Pressure sensor (Flow Monitor pump option)
B4
C1
C4
[mm]
[mm]
[mm]
-
58
37
139
90
39
-
68
38
139
90
39
H2
H3
D1
[mm]
[mm]
R 5/8
252
153
R 1 1/4
265
179
R 1 1/4
246
143
R 1 1/4
265
179

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ddi 60-10Ddi 150-4

Table of Contents